‎+7 (499) 500-24-60
Moscow, Udaltsova St., 81, bldg 2, office 6
RU|EN

Genset exhaust: back pressure, silencers, routing and gas cleaning

An exhaust line does three jobs: it carries gas away from the engine, cuts noise and must not cost power. A poorly designed line makes the engine lose power, run hot and burn more fuel. Here is what to check in the design, and what SCR and a particulate filter are.

1. What the line consists of

  • Flexible connection (bellows) as close to the exhaust manifold as possible: it absorbs vibration and thermal growth. Install it straight; on a bend it adds a lot of resistance.
  • Silencer (the primary one sits close to the engine).
  • Pipes and elbows on the shortest route, with long-radius elbows.
  • Hangers and supports: they carry the line weight, not the engine.
  • Condensate drain at the low point and a rain cap or angled cut at the end.

2. Back pressure is the main criterion

Back pressure is the resistance the engine works against when pushing gas out. It is measured at the turbocharger outlet or manifold at full load. Every engine datasheet states its limit. Supplier overviews put it at roughly 5–10 kPa for most engines, nearer the lower end for turbocharged ones; take your number from the engine datasheet, not from a web table.

Exceeding the limit costs power and raises exhaust temperature, fuel use, smoke and valve and turbocharger wear (manufacturer manuals say so directly). The limit is a budget spent by every element: pipe, elbows, silencer, catalyst or filter and cap. A catalyst or filter takes a significant and rising loss as soot builds up, so leave an ageing margin.

3. A feel for the numbers

Pressure drop in a pipe is estimated as ΔP = f × (L/D) × (ρv²/2), where L is the equivalent length including elbows, D the inner diameter and v the gas velocity. In one supplier's illustrative example for a 400 kW set (flow about 1.4 m³/s at 500 °C) the velocity is about 28 m/s in a 250 mm pipe and about 44 m/s in 200 mm, and friction loss grows roughly threefold. So a pipe the size of the engine outlet is often too small for a long run. A rule of thumb from an Azimut manual: start with the exhaust flange diameter and add 25 mm for every 6 m of length or three 90° elbows. It is a guide, not a replacement for a calculation from the engine data.

4. Which silencer

Catalogue noise grades are indicative. According to an Axces overview, the usual ranges are about 12–20 dB(A) for industrial, 18–25 residential, 25–35 critical and 32–42 hospital grades, and manufacturers differ by a few decibels. EGSA published standard 201S-2014 in 2014 to make this comparable: eight classes by dynamic insertion loss in 5 dB steps. Choose from the noise level required at a given point (see genset noise), not from the class name.

Exhaust noise is mainly low frequency, so the silencer is chosen with the firing frequency in mind: f = n × z / 120 (n = rpm, z = cylinders per pipe); for 12 cylinders at 1,500 rpm it is 150 Hz. A silencer reduces only exhaust noise. Engine, fan and alternator noise is handled by an enclosure, an acoustic room or a container (see containerised gensets).

5. Routing and safety

  • One line per set. A shared exhaust sends hot gas and condensate into the idle machine.
  • Thermal expansion. By one installation guide a pipe grows about 1.2 mm per metre per 100 °C; long runs are split with expansion joints.
  • Insulation indoors. Instructions call for dense mineral wool at least 50 mm thick in aluminium cladding: less burn risk and less heat in the room. Use sleeves and clearances where the pipe passes walls or roofs.
  • Condensate and rain. When the set is idle, steam condenses in the line. Drain at the low point, slope horizontal runs and protect the outlet from rain, or water reaches the engine at first start.
  • Where to discharge. Away from windows, fresh-air intakes and areas where people gather; gas must not be drawn back into the set's air intake. Minimum distances depend on the design, site rules and the manufacturer; we give no universal number.

6. Gas cleaning: SCR, filter, catalyst

Diesels that must meet US Tier 4 Final use:

  • SCR (selective catalytic reduction): urea solution (DEF, known in Russia as AdBlue) is injected ahead of the catalyst and turns NOx into nitrogen and water;
  • DOC, an oxidation catalyst that reduces hydrocarbons and CO;
  • DPF, a particulate filter that traps and burns off soot.

The configuration varies by maker: the Generac SD500 on a Perkins engine lists EGR, DOC, SCR and DPF, while the Kohler KD Tier 4 Final series lists SCR only. By a Cummins bulletin urea use is typically 3–5 % of fuel use; Loftin gives about 1 gallon per 20 gallons of fuel (5 %). In operation that means a separate urea tank with a limited shelf life, and at low load a filter can clog, so trade materials mention load banks and heating. A set with aftertreatment is larger and adds back pressure.

About regulations. Tier 4 is a US standard (40 CFR). An emergency standby set there is exempt from Tier 4 Final, while prime and peaking sets are covered. For Russia we found no comparable "tier" for gensets in verified sources, so we do not name one: emissions are regulated under federal law 7-FZ. Rosprirodnadzor explains that stationary gensets that are not self-propelled units must be included in the emission-source inventory and the permissible-emission project. Whether a dispersion calculation and a permit are needed, and which limits apply, is decided by the project and an environmental designer from your running hours and site.

Where it falls short

  • Figures here come from supplier and manufacturer overviews. For an order, use the datasheet of the specific engine.
  • Aftertreatment raises price, size and service burden (urea, filter regeneration).
  • We found no Russian numeric emission tier for gensets in verified sources.

Checklist

  1. Take exhaust flow, temperature and permitted back pressure from the engine datasheet.
  2. Add up the losses (pipe, elbows, silencer, catalyst, cap) and keep an ageing margin.
  3. Bellows at the manifold, hangers instead of engine load, expansion compensation.
  4. Insulation indoors, sleeves through walls.
  5. Condensate drain, slope, rain protection.

FAQ

What is exhaust back pressure and why does it matter?

It is the resistance of the exhaust line measured at the engine outlet at full load. Above the engine datasheet limit, exhaust temperature and fuel use rise, power falls and valves and turbocharger wear faster.

Can several gensets share one exhaust pipe?

Not recommended: hot gas and condensate reach the idle unit. Each set gets its own line.

What is SCR on a diesel genset?

Selective catalytic reduction: urea solution is injected into the exhaust ahead of a catalyst and converts NOx to nitrogen and water. By Cummins, urea use is about 3–5 % of fuel use.

Need help with exhaust for a specific project? Send engine data and layout — we will help choose the set. See also: fuel system, how to choose a genset.

Write to us

We will reply to info@levrus.ru shortly