Perkins 4000: British engines for 600–2 000 kW gensets
Perkins is known for small engines, but its 4000 Series is a large range for power plants: 6, 8, 12 and 16 cylinders, 23 to 61 litres.
History
- 1932 — Frank Perkins and Charles Chapman found the company in Peterborough, UK, to build high-speed diesels.
- 1959 Massey Ferguson, 1994 LucasVarity; 1997–1998 Caterpillar acquires Perkins (US$1.325 billion per Wikipedia).
- Perkins now quotes a 4–2 000 kW range of diesel and gas engines.
4000 Series data
| Model | Layout | Bore×stroke, mm | Displacement, L | 50 Hz standby, kWe | 50 Hz prime, kWe |
|---|---|---|---|---|---|
| 4006-23 | in-line 6 | 160×190 | about 23 | 660–720 | 600–640 |
| 4008 | in-line 8 | 160×190 | 30.6 | 800–880 | 720–800 |
| 4012-46 | V12 | 160×190 | 45.8 | 1 100–1 500 | 1 000–1 350 |
| 4016 | V16 | 160×190 | 61.1 | 1 600–2 000 | 1 480–1 800 |
Ratings are rounded from the Perkins 4000 Series brochure; each row spans several versions. Check the datasheet of the exact model.
What the numbers say
- One cylinder across the series (160×190 mm, 3.8 L), so parts and service are shared.
- Mean piston speed at 1 500 rpm is 9.5 m/s — high-speed class, closer to Cummins than to medium-speed machines.
- The 4016 (61.1 L) is 21 % larger than a KTA50 (50.3 L).
Reading a Perkins datasheet
- Electrical output is "typical": average alternator efficiency (95–96 % on 4008 and 4016) and power factor 0.8.
- Baseload (no overload), prime (80 % average load, 10 % overload for 1 hour in 12) and standby (up to 500 h/year, no overload) — compare quotes in one rating; see sizing guide.
- Ratings are ±3 % at 25 °C, 100 kPa, 30 % humidity.
Limits
- The range ends at 2 MW; above that see MTU or medium-speed sets.
- For 8 000 h/year duty compare cost of ownership using fuel consumption.
- Confirm origin, warranty and lead time for Russian projects.
No Perkins sets are in our catalogue at present: send us your specification and we will propose an equivalent from the diesel catalogue.