Waukesha VGF and VHP: rich-burn gas gensets, 0.6–1.6 MW

Waukesha is a US gas-engine brand for compressor stations and power plants. Our catalogue lists three models: VGF P48GSI, VHP7104GSI S5 and VHP9504GSI S5. All run on a rich (stoichiometric) mixture, which shapes both their strengths and their efficiency.

Who makes it

  • 1906 — Waukesha Motor Company founded in Waukesha, Wisconsin.
  • 1967 — VHP (Very High Power) series enters production.
  • 1974 — bought by Dresser Industries; 1995 — diesel line discontinued, gas engines only.
  • 2011 — General Electric completes the $3 billion acquisition of Dresser.
  • 2018 — Advent International buys GE Distributed Power; it becomes INNIO, keeping the Waukesha and Jenbacher brands.

Three models in the catalogue

ModelCyl.Bore×stroke, mmDispl., LSpeed at 50 Hz, rpmOutput
VGF P48GSIV16152×165481,500660 kW engine shaft power
VHP7104GSI S5 (engine L7044GSI S5)V12238×2161151,0001,235 kWe genset; 1,350 kWe at 60 Hz
VHP9504GSI S5 (engine P9394GSI)V16238×2161541,0001,600 kWe genset; 1,770 kWe at 60 Hz

Source: INNIO Waukesha data sheets (IWK-123060, IWK-123074, IWK-123039) and the 2023 rating table. Note the different bases: the VGF sheet gives shaft power, the VHP sheets give electrical output of the genset, so the models cannot be compared directly.

What the numbers show

  • VHP runs at 1,000 rpm on 50 Hz: mean piston speed about 7.2 m/s, against 10–11 m/s for 1,500 rpm gas gensets. VGF P48GSI at 1,500 rpm: 8.25 m/s.
  • Efficiency is lower than lean-burn. VHP9504GSI S5 draws 4,550 kW of fuel for 1,600 kWe, about 35%; VHP7104GSI S5 is also about 35%. An S&L Energie calculation sheet shows 33.6% for the VGF P48GSI at 660 kW. Lean-burn gensets reach 42–46% (see Caterpillar, MWM).
  • Reading the name. VGF letters give displacement: F 18 L, H 24 L, L 36 L, P 48 L. GSI is rich-burn, turbocharged and intercooled; GL is lean-burn; S5 is Series Five.

What a rich mixture gives

Waukesha offers the emPact system — engine, AFR2 air-fuel control and a three-way (NSCR) catalyst — to hold emissions as speed, load and fuel change. The manufacturer quotes 4,000-hour spark-plug and oil-change intervals for Series Five. The price is about 35% efficiency against 42–46% for lean-burn engines, i.e. more gas per kWh; calculate it as in the fuel-consumption article.

Gas pressure and quality

VGF P48GSI needs 1.72–3.45 bar supply pressure. The VHP7104GSID S5 low-fuel-pressure version lists a 11.7 kPa minimum. Below that, a booster compressor is needed. The S&L sheet states no liquid water or hydrocarbons in the gas, dew point at least 11 °C below gas temperature at the regulator inlet, and a filter-separator on non-pipeline gas.

Limits

  • Catalogue range is 0.6–1.6 MW; above that see MWM TCG 2032 (up to 4.5 MW).
  • Electrical efficiency is below Jenbacher, Caterpillar K and MWM; less important in CHP with heavy heat demand.
  • Service and spares for projects in Russia: confirm with the supplier.

See Waukesha gas gensets. Compare: Jenbacher, Caterpillar, MTU 4000 GS.

Write to us