Load module LEVRUS - NM-200kW-380 V-3-K (200 kW)
Composition and specifications of the load bank equipment NM-200kW-380 V-3-K | |
Equipment name | Load bank module NM-200kW-380 V-3-K |
Power | 200 kW |
Rated power of the steps | 4 x 50 kW The steps can be increased or decreased smoothly or abruptly, and power can be switched on either sequentially (for example, adding 50/100/200 kW at a time) or raised at once to 200 kW and reduced at once to 50 kW, depending on the requirements of the test procedure. |
Type of electrical load | Active resistive load |
Type of current in the power circuit | Three-phase alternating current, 50 Hz |
Rated voltage | ~400 V |
Power factor, cos (ϕ) | 0.99 |
Phase connection type | Star |
Operating mode | Continuous |
Ambient air temperature during operation of the load module | -25...+35 °C |
Fault protection | Full protection: - overheat protection; - fan fault protection; - air flow protection (AFP) and RCD; - short-circuit protection; - emergency stop button. |
Forced air cooling | Three-phase axial fan supplied from the source under test. |
Direction of the cooling air flow | Horizontal |
Control system | Built-in control panel. The control cabinet panel is intended for manual control of the load module and indication of operating and fault modes. |
Recording of electrical operating parameters | Digital three-phase multimeter SATEC or equivalent (optional), installation cost RUB 60,000 including VAT |
Degree of protection of the input distribution board / control panel | IP 54 |
Insulation resistance | In accordance with the requirements of the technical specifications and the Electrical Installation Regulations. |
Insulation class | 1 kV (1000 V) |
Resistive elements | Finned nichrome (NiCr 80/20) heating elements (steel with ceramic insulators), Russia. |
Circuit breakers | Contactors manufactured by IEK or equivalent; other brands by agreement, with a corresponding change in price. |
Noise level outside the container, no more than | 80 dBA |
Paint finish | Powder coating, RAL 5017 or in accordance with the technical specification |
Earthing of the load module | Two terminals (M10 threaded hole) on the outside of the load module enclosure |
Climatic design / Operation | UHL1. Outdoor operation is possible. All-weather enclosure, enclosure protection rating — IP 54 (with 4 bolts). |
Transportation | Resistance to transportation by land transport. |
Overall dimensions, no more than | Length 1000 mm / Width 800 mm / Height 1600 mm |
Weight, no more than | 270 kg |
Documentation | A complete set of documents in Russian, including the operation manual, electrical connection diagram, certificate of conformity and load module data sheet |
Maintainability | Collapsible modular construction, fully maintainable |
Maintenance | Requires no special maintenance. |
Design service life | At least 12 years subject to compliance with storage and operating conditions |
Design of load module NM-200KVT-380V-3-K
The 200 kW, 400 V load module consists of a single load unit in a metal box on a frame, on a chassis; the control panel is mounted inside the enclosure. The body of the load bank is made of St08PS sheet metal with a thickness of at least 1.5 mm.
The load module NM-200KVT-380V-3-K in the enclosure and the control panel will comply with the requirements set out in your specification:
metal enclosure on a frame for indoor installation with removable and opening panels for easy access inside the module, with protection rating IP 54 and control panel protection rating IP 54
resistive load element unit
control and monitoring cabinet with instrument panel
switching and connection unit
terminal unit for connecting power sources
axial fan
The load module NM-200KVT-380V-3-K will be supplied with a certificate, data sheet and operating manual.
* A long service life is only possible subject to the correct operating conditions described in the instructions.
The 200 kW load module is supplied fully assembled and completely ready for further operation; no additional installation on site is required (apart from connecting the cable to the power source under load and to the earthing circuit).