Load module LEVRUS - NM-150kW-380 V-3-K (150 kW)
Composition and characteristics of the load equipment LEVRUS - NM-150kW-380 V-3-K | |
Equipment name | Load module LEVRUS - NM-150kW-380 V-3-K |
Power | 150 kW |
Rated power of steps | 5 × 10; 2 × 50 kW The steps can be increased or decreased smoothly or abruptly; power can be switched on both sequentially (for example, adding 10/50/150 kW) and brought up immediately to 150 kW and reduced immediately to 10 kW — depending on the test procedure requirements. |
Type of electrical load | Resistive load |
Type of current in the power circuit | Three-phase alternating current, 50 Hz |
Rated voltage | ~400 V |
Power factor, cos (ϕ) | 0.99 |
Phase connection type | Star |
Operating mode | Continuous |
Ambient air temperature during operation of the load module | -25...+35 °C |
Emergency protection | Full protection: -overheating protection; -fan failure protection; -air flow protection (AFP) and RCD; -short-circuit protection; -emergency stop button. |
Forced air cooling | Three-phase axial fan powered from the source under load. |
Cooling air flow direction | Horizontal |
Control system | Built-in control panel. The control cabinet panel is intended for manual control of the load module and indication of operating and emergency modes. |
Recording of electrical operating parameters | Digital three-phase multimeter SATEC or equivalent (optional) 60 000 roubles including VAT |
Protection degree of the distribution board / control panel | IP 54 |
Insulation resistance | In accordance with the requirements of the technical specifications and Electrical Installation Code. |
Insulation class | 1 kV (1000 V) |
Resistive elements | Finned nichrome (NiCr 80/20) heating elements (steel with ceramic insulators), Russia. |
Circuit breakers | Contactors manufactured by IEK or equivalent; other brands by agreement, subject to a corresponding price change. |
Noise level outside the container, not more than | 80 dBA |
Painting | Powder coating, RAL 5017 or in accordance with the technical specification |
Earthing of the load module | Two terminals (M10 threaded hole) on the outside of the load module enclosure |
Climatic design / Operation | UHL1. Operation outdoors is possible. All-weather enclosure, enclosure protection degree — IP 54 (with 4 bolts). |
Transportation | Resistance to transportation by ground transport. |
Overall dimensions, not more than | Length 750 mm / Width 1200 mm / Height 1300 mm |
Weight, not more than | 270 kg |
Documentation | Full set of documents in Russian, including the operation manual, electrical connection diagram, certificate of conformity, and load module data sheet |
Maintainability | Collapsible design, full maintainability |
Maintenance | No special maintenance required. |
Design service life | At least 12 years subject to compliance with storage and operating conditions |
Load module design
The 150 kW, 400 V load module consists of a single load unit in a metal enclosure on a frame, on a chassis; the control panel is mounted inside the enclosure. The load complex housing is made of St08SS sheet metal with a thickness of at least 1.5 mm.
The load module LEVRUS - NM-150kW-380 V-3-K in an enclosure and the control panel will comply with the requirements set out in your specification:
metal enclosure on a frame for indoor installation with removable and hinged panels for easy access inside the module, with protection rating IP 54 and control panel protection rating IP 54
resistive load element unit
control and monitoring cabinet with instrument panel
switching and connection unit
terminal unit for connecting power sources
axial fan
The load module LEVRUS - NM-150kW-380 V-3-K will be supplied complete with a certificate, technical passport and operating manual.
* A long service life is only possible if the correct operating conditions described in the instructions are observed.
The 100 kW load module is supplied fully assembled and completely ready for further operation; it does not require additional on-site installation (except for connecting the cable to the power source under load and the earthing circuit).