The ST1102SL online UPS is used to ensure uninterrupted operation and reliable protection of single-phase electrical equipment with a total capacity of 2 kVA / 1.8 kW when mains voltage is absent.
Thanks to the improved power factor correction algorithm, the ST1102SL model performs excellently in conjunction with diesel gensets.
The ST1102SL is a double-conversion UPS, which allows the device to stabilise the input voltage over a wide range (90–295 V) with high accuracy (±2 %) without switching to battery, instantly and seamlessly transfer the load supply to the battery when mains voltage fails, and supply the load with an ideal sinusoidal voltage.
Installation and connection
The ST1102SL has a compact metal housing designed for floor-standing installation. The device is mounted on swivel castors and can be placed on any flat horizontal surface.
For connecting electrical equipment, the model has two European sockets, three “computer” sockets (C13) and one C19 socket. The device is connected to the mains via a C20 inlet.
Battery operation
The ST1102SL model has built-in batteries with a capacity of 9 Ah and a charger (1 A current).
Control panel
Monitoring and adjustment of the main operating parameters of the product are carried out using a control panel with an LCD display, four function keys and five LED indicators.
Cooling system
The device is cooled by two low-noise fans with an adaptive operating mode.
Protection
The ST1102SL UPS uses a modern multi-level protection system and an electronic bypass.
Monitoring tools
The ST1102SL offers extensive capabilities for organising local/remote monitoring and control of its operation. For this purpose, expansion cards are connected to the UPS and are purchased separately.
The operation of the UPS with an installed card can be monitored directly in a web browser or in the Shtyl Device Manager (SDM) software.
| Built-in batteries |
| Battery type |
sealed, AGM technology |
| Built-in batteries |
yes |
| General specifications |
| Current |
AC |
| Apparent power, kVA |
2 |
| Active power, kW |
1,8 |
| Form factor |
floor-standing |
| Country of manufacture |
Russia |
| Main |
| Topology |
on-line |
| Input characteristics |
| Generator compatibility |
yes |
| Input mains type |
single-phase three-wire (L, N, PE) |
| Operating input voltage range, V |
175-295 at 100% load, 155-295 at 75% load, 120-295 at 50% load |
| Rated input frequency, Hz |
50 |
| Rated input voltage, V |
220 |
| Soft start |
yes |
| Output characteristics |
| Efficiency, % |
in on-line mode 95, when operating via bypass or in ECO mode 99, in battery mode 86 |
| Output voltage type |
single-phase |
| Rated output frequency, Hz |
при работе от сети – соответствует частоте сети
при работе от АБ – устанавливается пользователем: 50/60 (по умолчанию – 50) |
| Rated output voltage, V |
220 |
| Stabilisation accuracy, % |
±2 |
| Control panel and interfaces |
| Audible alarm |
battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0,5 s), overload and UPS fault (continuous) |
| Indication |
status, mains, bypass, inverter, batteries |
| LCD display |
display of system operating status and main input and output parameters |
| Options |
RS-232, mini-USB, USB, Ethernet, RS-485, «Dry» contacts |
| Connection |
| Input mains |
IEC-320-C20 |
| Load (output sockets) |
IEC-320-C13 (3 pcs.), EURO F-type with grounding (2 pcs.), IEC-320-C19 (1 pc.) |
| Reliability and performance characteristics |
| Cooling type |
forced air cooling (built-in fan with speed control) |
| Degree of protection against dust and moisture |
IP20 |
| Installation |
indoor |
| Protection |
Output overload, Short circuit, Overheating, Surge protection, High-frequency noise protection, Deep battery discharge protection, UPS fault protection, Electronic automatic bypass |
| Temperature range, °C |
operating temperature from +5 to +40, storage temperature from -40 to +40 |
| Warranty period, months |
24 |