LEVRUS LLC has won another tender to supply Shtil AC UPS to the All-Russian Research Institute of Canning Technology, a branch of the Federal Research Centre for Food Systems named after V.M. Gorbatov, RAS. The delivery includes the online models ST1101L, SR1101L and ST1103L, which are not inferior to foreign equivalents and are better in a number of parameters.
Brief equipment description
SR1101L UPS uses online topology to provide uninterrupted operation and high-quality protection against mains voltage fluctuations for single-phase loads up to 1000 VA / 900 W.
The SR1101L works excellently with diesel generator sets thanks to an improved power factor correction algorithm. With double conversion, the UPS maintains stable output voltage across a wide input voltage range of 90–295 V without switching to batteries, transfers the load to the batteries instantly and without interruption when the mains fails, and supplies the load with a true sinusoidal voltage at an accurate value.
Cooling is provided by a low-noise fan whose speed depends on the load level.
Installation and connection. The SR1101L is rack-mountable and is installed on 19-inch rails in telecommunications cabinets and racks. Two types of connectors are provided for connecting the load: one Schuko socket and three C13 computer sockets. The input AC voltage is connected via a C14 connector.
Control panel. The main operating parameters of the unit are monitored and set using an LCD, four function keys and five LED indicators.
Battery operation. Battery operation of connected equipment is provided by built-in batteries (9 Ah) and a charger (1 A). At 100% load, the batteries will provide backup power for 5 minutes.
Protection. The SR1101L UPS uses a modern multi-level protection system with automatic UPS restart after the fault cause is cleared.
Monitoring. The rear panel of the UPS has two slots for optional interface cards that enable local or remote monitoring of the device. Four interface card models are available with the following interfaces:
- RS-232 (Megatec protocol);
- RS-485 (Modbus RTU/Shtil protocols);
- USB and mini-USB;
- Ethernet (Web/SNMP/NTP/Modbus TCP/Shtil protocols);
- dry contacts.
After installing a card, the UPS can be monitored and managed in two ways: via a web browser or using Shtyl Device Manager (SDM) software. The cards are not included as standard and must be purchased separately.
Online UPS SR1103L is used for uninterrupted operation of single-phase electrical equipment with a total load of 3 kVA / 2.7 kW when the mains is absent or subject to voltage fluctuations. Thanks to an improved power factor correction algorithm, the SR1103L works excellently with diesel generator sets. Double-conversion technology stabilises the output voltage across a wide input voltage range of 90–295 V with ±2% accuracy without switching to batteries, transfers the load to the batteries instantly and without interruption when the mains fails, and supplies the load with an ideal sinusoidal voltage.
Online UPS ST1101L is used for uninterrupted operation and reliable protection of single-phase electrical equipment with a total load up to 1000 VA / 900 W when the mains voltage fails. Thanks to an improved power factor correction algorithm, the ST1101L works excellently with diesel generator sets. Double-conversion technology stabilises the output voltage across a wide input voltage range of 90–295 V with ±2% accuracy without switching to batteries, transfers the load to the batteries instantly and without interruption when the mains fails, and supplies the load with an ideal sinusoidal voltage.