The SM180 (2x30) modular online UPS provides uninterrupted power supply and protects three-phase electrical equipment from unstable voltage in the 380 V mains, for example:
- telecommunications and server equipment;
- IT and computer equipment;
- Hi-Tech audio and video equipment;
- electrical equipment for the retail sector;
- high-power household electrical equipment.
The SM180 (2x30) is a robust metal cabinet housing two 30 kVA /27 kW power modules and other components. The cabinet door has a dust filter.
Connecting additional power modules allows the output power of the power system to be increased to 180 VA /162 kW, and parallel connection of up to 3 SM180 UPS units fully equipped with modules – to 540 kVA / 486 kW.
The SM180 (2x30) also supports redundancy technologies based on UPS modules or units to build highly reliable configurations.
The SM180 (2x30) uses advanced double-conversion technology in its operation, which provides:
- operation over a wide mains voltage range (228-478 V) without switching to battery power;
- instant and seamless transfer of the load power to the battery when the mains voltage fails and back when it is restored;
- continuous supply of the load with sinusoidal voltage of high accuracy (±1.5%);
- maximum protection of the load from adverse effects of the mains;
- full independence of the output voltage characteristics from the mains condition.
Hot-swap replacement of a failed power module is provided (without de-energising the UPS and the load). In this case, the load power will be distributed evenly among the operating redundant modules, if they were installed.
Connection
The mains and load are connected to the UPS via busbars.
Battery operation
The SM180 (2x30) has no built-in batteries but can provide long-term autonomous operation of the load by connecting external batteries. For correct selection of external batteries and their installation solutions, please contact the specialists of the SHTYL Group factory.
The UPS is equipped with a built-in charger; its current is set in the range from 1 to 20% of the UPS power.
Control panel
A modern control panel is fitted on the UPS door, comprising an LCD display and LED indicators. They allow convenient monitoring of the device's operation and basic settings to be made.
The LCD display shows the input and output voltage, input frequency, apparent and active load power, UPS load percentage of its rated power, the alarm log and other device parameters.
The LED indicators signal the status of the UPS itself and of its individual units: rectifier, batteries, bypass circuit, inverter and output.
The power module installed inside the UPS has its own LCD display, which shows its operating parameters and allows its status to be monitored.
Protection
The SM180 (2x30) is equipped with a built-in protection system against:
- overload and short circuit;
- internal overheating;
- high-frequency mains interference and impulse overvoltages;
- switching transients and non-linear distortion;
- "deep" battery discharge.
The central electronic bypass allows automatic, uninterrupted switching of the load supply to the mains in the event of an overload or device failure
The technical bypass enables manual transfer of the load power to the mains when the UPS needs to be repaired or serviced without interrupting the load operation.
Monitoring tools
The SM180 (2x30) offers functionality for local/remote monitoring of the device's operation.
For this purpose, dry contacts, USB and RS-232 ports, as well as an Ethernet interface supporting SNMP, SHTYL and other protocols are used.
UPS operation is conveniently monitored using Shut Down Manager or Shtyl Device Manager software.
The model also has an EPO port for remote emergency shutdown.
- Advantages