The SM120 (1x20) modular online UPS is the optimal solution for ensuring uninterrupted operation and reliable protection against voltage fluctuations in the 380 V mains for critical three-phase loads, for example:
- data centres, communication nodes and workstations;
- network and server equipment;
- IT infrastructure of offices and enterprises;
- electrical equipment of banks and shopping and entertainment centres.
SM120 (1x20) is a robust metal cabinet housing a 20 kVA /18 kW power module and other device components. The cabinet door has a dust filter.
Connecting additional power modules allows the output power of the power system to be increased to 120 VA /108 kW, and parallel connection of up to 3 SM120 UPS units fully equipped with modules – to 360 kVA / 324 kW.
SM120 (1x20) also supports the use of redundancy technologies based on UPS modules or units to build highly reliable configurations.
The SM120 UPS (1x20) is built on the basis of double conversion technology, which provides:
- operation over a wide mains voltage range (228-478 V) without switching to battery power;
- instant and seamless transfer of the load power to the battery when the mains voltage fails and back when it is restored;
- continuous supply of the load with sinusoidal voltage of high accuracy (±1.5%);
- maximum protection of the load from adverse effects of the mains;
- full independence of the output voltage characteristics from the mains condition.
Hot-swap replacement of a failed power module is provided (without de-energising the UPS and the load). In this case, the load power will be distributed evenly among the operating redundant modules, if they were installed.
Connection
The electrical equipment and mains are connected to the UPS via busbars.
Battery operation
The SM120 UPS (1x20) does not contain built-in batteries, but is capable of providing long-term autonomous operation of the load by connecting external batteries. For the correct selection of external batteries and solutions for their installation, please contact the specialists of the SHTYL Group plant.
The UPS is also equipped with a built-in charger; its current is set in the range from 1 to 20% of the UPS power.
Control panel
A modern control panel is fitted on the UPS door, comprising an LCD display and LED indicators. They allow convenient monitoring of the device's operation and basic settings to be made.
The LCD display shows the input and output voltage, input frequency, apparent and active load power, UPS load percentage of its rated power, the alarm log and other device parameters.
The LED indicators signal the status of the UPS itself and of its individual units: rectifier, batteries, bypass circuit, inverter and output.
The power module installed inside the UPS has its own LCD display, which shows its operating parameters and allows its status to be monitored.
Protection
The SM120 (1x20) is equipped with a modern protection system against:
- overload and short circuit;
- internal overheating;
- high-frequency mains interference and impulse overvoltages;
- switching transients and non-linear distortion;
- "deep" battery discharge.
The centralised electronic bypass allows automatic, uninterrupted switching of the load supply to the mains in the event of an overload or device failure.
The technical bypass enables manual transfer of the load supply to the mains when repair or servicing of the UPS is required without interrupting the operation of the connected equipment.
Monitoring tools
The SM120 (1x20) offers functionality for local/remote monitoring of the device's operation.
For this purpose, dry contacts, USB and RS-232 ports, as well as an Ethernet interface supporting SNMP, SHTYL and other protocols are used.
UPS operation is monitored in Shut Down Manager or Shtyl Device Manager software.
The model also has an EPO port for remote emergency shutdown.
- Advantages