‎+7 (499) 500-24-60
Moscow, Udaltsova St., 81, bldg 2, office 6
Single-phase UPS

SHTYL SW300L UPS kit (300 VA/225 W) with battery for 6.5 h

  • Brand: Shtil
  • Product Code: SW300L-150Ah
  • Availability: Pre-order
63 486 ₽

The online UPS SW300L with an external 150 Ah battery housed in the battery rack BS-12-2W will provide uninterrupted power for more than 6.5 h (at 80% load) to electrical consumers with a power of 300 VA/225 W, for example:

  • gas boiler and circulation pump;
  • personal computer;
  • water treatment systems;
  • audio systems;
  • television and other low-power household loads.

Battery runtime at other UPS load levels is shown on the Battery operation tab.

In addition to backup power supply, the UPS can protect the load from voltage fluctuations and electrical interference. Its power factor corrector algorithm has been improved, allowing the device to operate fully in conjunction with generators.

The operation of the SW300L UPS is based on double power conversion technology, which allows the device to:

  • to perform voltage stabilisation in an extended range (90-295 V) with high accuracy (±2%) and without switching to autonomous mode;
  • instantly transfer the load power to the battery when the mains parameters go outside the permissible range;
  • to supply consumers with a voltage with an ideal sine wave.

The power supply is equipped with a convection cooling system, completely silent in operation.

Installation and connection

The SW300L is mounted on any flat vertical surface that can withstand a load of 4 kg. Installation is carried out using self-tapping screws. The battery rack is placed on the floor.

Batteries are installed in the rack strictly in accordance with the operating instructions. It is important that the rack circuit breaker is in the OFF position and its cable is disconnected from the UPS.

The UPS is connected to the mains via a cord with a Schuko plug. The rack with the installed battery is connected to the already switched-on power supply via a TD50A-TD50A cable. The load is connected to the UPS last.

All components intended for installing and connecting the devices are included in the scope of delivery.

Control panel

The UPS operation is monitored using the LED indicators located on the front panel:

  • "Status" – occurrence of alarms;
  • "Bypass" – operation via the bypass circuit/ECO mode;
  • "Battery" – battery status.

Assessing the status of all three indicators allows the operating mode of the device to be determined.

The Mode Change function key allows you to select the UPS operating mode: online, bypass or ECO. It can also be used (by holding for 3 seconds) to run a battery test – 10 seconds of forced battery-powered load supply.

Battery charging

Charging of the connected 150 Ah battery is performed by the charger built into the UPS with a current of 6 A.

The SW300L uses modern technologies to reduce charging time and extend battery life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against deep discharge), notify the user of battery wear and predict the autonomy time at the current load (the value is displayed in the device's web interface; a monitoring card is required for connection).

Protection

The SW300L has electronic protection against:

  • short circuit;
  • sustained output overload;
  • internal overheating.

Automatic restart of the UPS is supported after the cause of the electronic protection tripping has been eliminated.

In addition, the device features:

  • with surge and mains interference protection;
  • emergency protection against operational faults (when it is activated, the device either switches off the load or transfers its power supply to the mains without interruption via the bypass).

High-frequency filters protect the mains from interference in the 150 kHz - 30 MHz range and the load (from phase-to-neutral interference up to 2.5 kHz).

The battery rack BS-12-2W is equipped with a built-in 2P C32 circuit breaker for battery protection.

Monitoring tools

A monitoring card can be installed in the SW300L to monitor its status and configure its parameters. The UPS supports several compatible monitoring card models with the following interfaces:

  • RS-232 (Megatec protocol);
  • RS-485 (SHTYL protocol);
  • USB and mini-USB;
  • Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
  • "dry" contacts;
  • temperature sensor.

With the card installed, the UPS status can be monitored in a web browser or in the Shtyl Device Manager (SDM) software. The power supply parameters (for example, setting its output voltage) are edited only using the Shtyl Device Manager software when the computer is locally connected to the UPS via the USB interface or the RS-232 interface.

The cards are not included in the standard scope of supply and are purchased separately.

All SHTYL brand solutions for autonomous load power supply offer an excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.

  • Advantages

General specifications
Apparent power, kVA 0,3
Active power, kW 0,225
Form factor wall-mounted
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Country of manufacture Russia
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Input power factor 0,99
Limiting input voltage range, V 90-295
Maximum input current, A 1,9
Operating input voltage range, V 175-295 at 100% load, 155-295 at 75% load, 120-295 at 50% load
Power consumption in no-load mode, W 16
Rated input frequency, Hz 50
Rated input voltage, V 230
Soft start yes
Permissible input frequency range, Hz 45-65
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -5, -10, -15, -20, -25 (default: -15)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +10)
Maximum bypass current, A 4,5
Output characteristics
Crest factor 3:1
Maximum output current, A 1,2
Output power factor 0,75
Output voltage type single-phase
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50 (default)/ 60 (monitoring card required)
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2.5 with linear load, <4 with non-linear load
Rated AC output voltage, V 230
Output voltage waveform pure sine wave
Efficiency in online mode, % 91
Efficiency in battery mode, % 82
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,2
Overload capacity (when operating in on-line mode or from batteries) 101-105% – for 3 min, 105-130% – for 60 s, 130-150% – for 1 s, above 150% – for 0.2 s
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 7
Overload capacity (when operating via bypass or in ECO mode) 200% for 40 s
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0.5 s), overload and UPS fault (continuous)
Ethernet option (monitoring card required)
LED indication status, bypass, battery
RS-485 option (monitoring card required, data exchange only with SHTYL equipment)
Indication type LED indication
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys "On", "Off", "Mode change"
USB option (monitoring card required)
Temperature sensor option (monitoring card required)
Connection
Input mains power cable with Euro plug
Load (output sockets) EURO F-type with grounding (1 pc.)
UPS connection connector type TD50A
Reliability and performance characteristics
Cooling type convection (fanless)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years 10
Warranty period, months 24 (12 per battery)
Operating temperature range, °C from 0 to +40 (recommended battery operating temperature - from +20 to +25)
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour grey
Weight, kg 69
Overall dimensions HxWxD (unpacked), mm 283x285x93
Overall dimensions of the rack HxWxD, mm 382x630x324
Batteries (battery packs)
Battery availability external
Hot-swap of built-in batteries no
Battery runtime (at 80% UPS load) 6.5 h
Rated battery voltage, V 12
Battery type sealed, maintenance-free, lead-acid
Battery service life, years 10-12 (depending on operating conditions)
Battery management functionality deep discharge protection (LVD), charge temperature compensation, 10-second battery test
Cold start yes
Rated charge current of the built-in charger, A 6
Capacity of one 12 V battery, Ah 150
Number of external 12 V batteries, pcs. 1
Battery protection built-in 2P C32 circuit breaker

Write to us

We will reply to info@levrus.ru shortly