The online UPS SW300L with an external 150 Ah battery housed in the battery rack BS-12-2W will provide uninterrupted power for more than 6.5 h (at 80% load) to electrical consumers with a power of 300 VA/225 W, for example:
- gas boiler and circulation pump;
- personal computer;
- water treatment systems;
- audio systems;
- television and other low-power household loads.
Battery runtime at other UPS load levels is shown on the Battery operation tab.
In addition to backup power supply, the UPS can protect the load from voltage fluctuations and electrical interference. Its power factor corrector algorithm has been improved, allowing the device to operate fully in conjunction with generators.
The operation of the SW300L UPS is based on double power conversion technology, which allows the device to:
- to perform voltage stabilisation in an extended range (90-295 V) with high accuracy (±2%) and without switching to autonomous mode;
- instantly transfer the load power to the battery when the mains parameters go outside the permissible range;
- to supply consumers with a voltage with an ideal sine wave.
The power supply is equipped with a convection cooling system, completely silent in operation.
Installation and connection
The SW300L is mounted on any flat vertical surface that can withstand a load of 4 kg. Installation is carried out using self-tapping screws. The battery rack is placed on the floor.
Batteries are installed in the rack strictly in accordance with the operating instructions. It is important that the rack circuit breaker is in the OFF position and its cable is disconnected from the UPS.
The UPS is connected to the mains via a cord with a Schuko plug. The rack with the installed battery is connected to the already switched-on power supply via a TD50A-TD50A cable. The load is connected to the UPS last.
All components intended for installing and connecting the devices are included in the scope of delivery.
Control panel
The UPS operation is monitored using the LED indicators located on the front panel:
- "Status" – occurrence of alarms;
- "Bypass" – operation via the bypass circuit/ECO mode;
- "Battery" – battery status.
Assessing the status of all three indicators allows the operating mode of the device to be determined.
The Mode Change function key allows you to select the UPS operating mode: online, bypass or ECO. It can also be used (by holding for 3 seconds) to run a battery test – 10 seconds of forced battery-powered load supply.
Battery charging
Charging of the connected 150 Ah battery is performed by the charger built into the UPS with a current of 6 A.
The SW300L uses modern technologies to reduce charging time and extend battery life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against deep discharge), notify the user of battery wear and predict the autonomy time at the current load (the value is displayed in the device's web interface; a monitoring card is required for connection).
Protection
The SW300L has electronic protection against:
- short circuit;
- sustained output overload;
- internal overheating.
Automatic restart of the UPS is supported after the cause of the electronic protection tripping has been eliminated.
In addition, the device features:
- with surge and mains interference protection;
- emergency protection against operational faults (when it is activated, the device either switches off the load or transfers its power supply to the mains without interruption via the bypass).
High-frequency filters protect the mains from interference in the 150 kHz - 30 MHz range and the load (from phase-to-neutral interference up to 2.5 kHz).
The battery rack BS-12-2W is equipped with a built-in 2P C32 circuit breaker for battery protection.
Monitoring tools
A monitoring card can be installed in the SW300L to monitor its status and configure its parameters. The UPS supports several compatible monitoring card models with the following interfaces:
- RS-232 (Megatec protocol);
- RS-485 (SHTYL protocol);
- USB and mini-USB;
- Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
- "dry" contacts;
- temperature sensor.
With the card installed, the UPS status can be monitored in a web browser or in the Shtyl Device Manager (SDM) software. The power supply parameters (for example, setting its output voltage) are edited only using the Shtyl Device Manager software when the computer is locally connected to the UPS via the USB interface or the RS-232 interface.
The cards are not included in the standard scope of supply and are purchased separately.