‎+7 (499) 500-24-60
Moscow, Udaltsova St., 81, bldg 2, office 6
Single-phase UPS

SHTYL STR500SL-18 online UPS (500 VA / 400 W)

  • Brand: Shtil
  • Product Code: STR500SL18
  • Availability: Pre-order
39 800 ₽

The STR500SL-18 is a high-performance single-phase online UPS in a floor-standing/rack-mount design. The model will provide backup power supply and protection against voltage surges for critical equipment with a total capacity of up to 500 VA/400 W. Examples of the load may include:

  • computer equipment;
  • network equipment;
  • security systems;
  • emergency lighting;
  • low-power household appliances.

The UPS functions efficiently in combination with household generators thanks to an improved power factor corrector algorithm.

The STR500SL-18 UPS is based on double-conversion technology, which provides:

  • continuous voltage stabilisation in the 90-295 V range with high accuracy (±2%) without switching to the batteries;
  • instant and seamless switching of appliance power to autonomous mode when the power fails;
  • power supply to the load with an ideal sine wave voltage in any operating mode.

Installation and connection

The universal cabinet STR500SL-18 allows installation in two ways:

  • into a 19-inch rack in a horizontal position (if the device is not placed on a shelf, it is recommended to additionally purchase a rack mounting kit);
  • on the floor, a table or a shelving unit in a vertical position.

To connect the load, the UPS enclosure has a block of three "computer" C13 sockets. The device is connected to the mains via a 1.5 m mains cable with a Euro plug.

Battery operation

Battery operation of the load is provided by the built-in charger (current 5 A) and a battery block with four batteries with a total capacity of 18 Ah. At 100% load, the backup power supply to the connected electrical equipment will last 22 minutes (Battery runtime table).

Attention! The internal battery block is initially not connected to the UPS. This is done to prevent self-discharge of its battery. Before the first start-up of the device, the connector in the battery compartment must be connected. For more details, see the operation manual.

To extend battery runtime up to 2.5 h at 100% load, connection of up to 4 external battery modules BMRT-24-18 is provided for (Battery runtime table).

The STR500SL-18 uses modern technologies to reduce charging time and extend battery service life (intelligent charging and charge temperature compensation).

In addition, the model features special algorithms that allow:

  • disconnect the battery at 80-85% discharge (protection against deep discharge);
  • notify the user in advance of battery wear;
  • accurately predict the autonomy time at the current load.

Control panel

For monitoring and configuring operating parameters, the STR500SL-18 UPS provides a control panel with an LCD display, function keys and five LED indicators:

  • "Status" – indicates the device operating mode;
  • "Mains" – indicates mains status;
  • "Bypass" – indicates a switch to bypass/ECO mode;
  • "Inverter" – indicates inverter operation;
  • "Battery" – shows the battery status.

Information on the LCD display:

  • input and output voltage values;
  • UPS load percentage;
  • battery voltage values and their status;
  • active and apparent load power;
  • alarms with indication of their causes.

Settings on the LCD display:

  • start-up and operation mode;
  • output voltage;
  • nominal frequency when operating from the battery;
  • bypass mode;
  • on/off of the audible alarm;
  • battery parameters (capacity, voltage, temperature compensation, etc.);
  • battery test (time and period).

Three types of battery test are available:

  • 10-second (load supply for 10 seconds);
  • for a specified time (powering the load for a specified time);
  • to full discharge (powering the load until the battery is fully discharged, with measurement of its residual capacity).

Cooling system

The device is equipped with a low-noise fan with automatic speed control, located on the rear panel.

Monitoring tools

A monitoring card can be installed in the STR500SL-18 to monitor its status and configure its parameters. The UPS supports several compatible monitoring cards with the following interfaces:

  • RS-232 (Megatec protocol);
  • RS-485 (Modbus RTU/SHTYL protocols);
  • USB and mini-USB;
  • Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
  • "dry" contacts;
  • temperature sensor.

With the card installed, the UPS status can be monitored in a web browser or in the Shtyl Device Manager (SDM) software. To view the UPS status remotely in a web browser, the device must be connected to the internet via the Ethernet connector. An IC-SNMP/Web or IC-SNMP/mini-USB interface expansion card is required to set up such a connection.

The UPS parameters of the STR500SL-18 are edited via the control panel or the Settings menu of the Shtyl Device Manager software when the computer is locally connected to the UPS via the USB interface or the RS-232 interface.

Please note! The monitoring card is not included in the scope of supply and must be purchased separately.

Protection

The STR500SL-18 has electronic protection against:

  • overload;
  • short circuit;
  • internal overheating.

Once the cause of the fault is eliminated, the device automatically restarts.

The built-in varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response time – 50 µs) provides surge protection.

High-frequency filters protect the mains from interference in the 150 kHz - 30 MHz range and the load (from phase-to-neutral interference up to 2.5 kHz).

The UPS is also equipped with protection against operating faults (if they occur, the load is either disconnected or transferred without interruption via bypass to the mains).

The STR500SL-18 online UPS offers an excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.

  • Advantages

General specifications
Apparent power, kVA 0,5
Active power, kW 0,4
Form factor floor-standing/rack-mount
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Country of manufacture Russia
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Input power factor 0,99
Limiting input voltage range, V 90-295
Maximum input current, A 3,6
Operating input voltage range, V 175-295 at 100% load, 155-295 at 75% load, 120-295 at 50% load
Power consumption in no-load mode, W 20
Rated input frequency, Hz 50
Rated input voltage, V 220
Soft start yes
Permissible input frequency range, Hz 45-65
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % 5, -10, -15, -20, -25 (default value: -20)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +20)
Maximum bypass current, A 5
Output characteristics
Crest factor 3:1
Maximum output current, A 2,3
Output power factor 0,8
Output voltage type single-phase
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50 (default)/ 60
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2.5 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 96
Efficiency in battery mode, % 81
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,2
Overload capacity (when operating in on-line mode or from batteries) 101-105% – for 3 min, 105-130% – for 60 s, 130-150% – for 1 s, above 150% – for 0.2 s (followed by switching to bypass)
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 7
Overload capacity (when operating via bypass or in ECO mode) 200% for 40 s
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0.5 s), overload and UPS fault (continuous)
Ethernet option (monitoring card required)
LCD display display of system operating status and main input and output parameters
LED indication status, mains, bypass, inverter, batteries
RS-485 option (monitoring card required, data exchange only with SHTYL equipment)
Indication type LCD display and LED indication
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys "On", "Off", "Up", "Enter"
USB option (monitoring card required)
Temperature sensor option (monitoring card required)
Connection
Input mains IEC-320-C14
Load (output sockets) IEC-320-C13 (3 pcs.)
Priority disconnection of non-priority load no
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years at least 10
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour black
Weight, kg 20
Rack mounting height, U 2
Overall dimensions HxWxD (unpacked), mm 89x440x474 (rack, excluding brackets for horizontal mounting) 89x482x474 (rack, full dimensions) 467x207x474 (floor-standing)
Overall dimensions HxWxD (packed), mm 135x540x490
Batteries (battery packs)
Battery availability built-in
Hot-swap of built-in batteries yes
Battery runtime (at 80% UPS load) 30 min
Battery runtime at 100% (50%) UPS load, min 22 (50)
Internal battery capacity, Ah 18
Number of built-in 12 V batteries, pcs. 4
Rated battery voltage, V 24
Battery type sealed, maintenance-free, lead-acid
Battery service life, years up to 7 (depending on operating conditions)
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A 5
Built-in battery charge time, h no more than 8 (up to 90% capacity)

Write to us

We will reply to info@levrus.ru shortly