‎+7 (499) 500-24-60
Moscow, Udaltsova St., 81, bldg 2, office 6
Single-phase UPS

SHTYL STR500SL online UPS (500 VA / 400 W)

  • Brand: Shtil
  • Product Code: STR500SL
  • Availability: Pre-order
34 570 ₽

The STR500SL is a highly reliable floor-standing/rack-mount online UPS. The model is capable of providing backup power supply and protection against unstable voltage for a load with a total capacity of up to 500 VA/400 W, for example:

  • servers and computers;
  • network equipment;
  • security, alarm and video surveillance systems;
  • musical equipment and audio-visual equipment;
  • low-power household appliances.

Thanks to the improved power factor corrector operating algorithm, the UPS functions efficiently in conjunction with household generators.

Thanks to the double conversion principle used in the STR500SL, the device:

  • performs continuous voltage stabilisation in the 90-295 V range with high accuracy (±2%) without switching to batteries;
  • provides an instantaneous and seamless transfer of the equipment to autonomous operation in the event of a power failure;
  • supplies the load with voltage having a perfect sine wave in any operating mode.

The device is equipped with a low-noise fan with automatic speed control.

Installation and connection

The universal cabinet STR500SL allows installation in two ways:

  • into a 19-inch rack in a horizontal position (if the device is not placed on a shelf, it is recommended to additionally purchase a rack mounting kit);
  • on the floor, a table or a shelving unit in a vertical position.

To connect the load, three "computer" C13 sockets are provided. The device is connected to the mains via a 1.5 m mains cable with a "Schuko - C13" plug.

Battery operation

The STR500SL UPS has a built-in charger (current 1 A) and a battery block with two 9 Ah batteries, thanks to which the device provides backup power to equipment for 10 minutes at 100% load (Battery Runtime Table).

Attention! The internal battery block is initially not connected to the UPS. This is done to prevent self-discharge of its battery. Before the first start-up of the device, the connector in the battery compartment must be connected. For more details, see the operation manual.

The STR500SL uses modern technologies to reduce charging time and extend battery service life (intelligent charging and charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against «deep» discharge), notify the user of its wear and predict the autonomy time of connected electrical appliances.

Control panel

The main operating parameters of the STR500SL are monitored and configured on the control panel with an LCD display, function keys and LED indicators:

  • "Status" – indicates the device operating mode;
  • "Mains" – indicates mains status;
  • "Bypass" – indicates a switch to bypass/ECO mode;
  • "Inverter" – indicates inverter operation;
  • "Battery" – shows the battery status.

Information on the LCD display:

  • input and output voltage values;
  • UPS load percentage;
  • battery voltage values and their status;
  • active and apparent load power;
  • alarms with indication of their causes.

Settings on the LCD display:

  • start-up and operation mode;
  • output voltage;
  • nominal frequency when operating from the battery;
  • bypass mode;
  • on/off of the audible alarm;
  • battery parameters (capacity, voltage, temperature compensation, etc.);
  • battery test (time and period).

Three types of battery test are available:

  • 10-second (load supply for 10 seconds);
  • for a specified time (powering the load for a specified time);
  • to full discharge (powering the load until the battery is fully discharged, with measurement of its residual capacity).

Monitoring tools

A monitoring card can be installed in the STR500SL to monitor its status and configure its parameters. The UPS supports several compatible monitoring cards with the following interfaces:

  • RS-232 (Megatec protocol);
  • RS-485 (SHTYL protocol);
  • USB and mini-USB;
  • Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
  • "dry" contacts;
  • temperature sensor.

With the card installed, the UPS status can be monitored in a web browser or in the Shtyl Device Manager (SDM) software. To view the UPS status remotely in a web browser, the device must be connected to the internet via the Ethernet connector. An IC-SNMP/Web or IC-SNMP/mini-USB interface expansion card is required to set up such a connection.

The UPS parameters of the STR500SL are edited via the Settings menu of the Shtyl Device Manager software when the computer is locally connected to the UPS via the USB interface or the RS-232 interface.

Please note! The monitoring card is not included in the scope of supply and must be purchased separately.

Protection

The STR500SL has electronic protection against:

  • overload;
  • short circuit;
  • internal overheating.

Once the cause of the protection trip is eliminated, the UPS automatically restarts.

In addition, the device features protection against surge voltages and high-frequency mains interference, as well as emergency protection against any malfunctions (when it is triggered, the device switches off the load or transfers its power without interruption to the mains via bypass).

The STR500SL online UPS offers an excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.

  • Advantages

General specifications
Apparent power, kVA 0,5
Active power, kW 0,4
Form factor floor-standing/rack-mount
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Country of manufacture Russia
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Input power factor 0,99
Limiting input voltage range, V 90-295
Maximum input current, A 2,7
Operating input voltage range, V 175-295 at 100% load, 155-295 at 75% load, 120-295 at 50% load
Power consumption in no-load mode, W 20
Rated input frequency, Hz 50
Rated input voltage, V 220
Soft start yes
Permissible input frequency range, Hz 45-65
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -5, -10, -15, -20, -25 (default: -20)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +20)
Maximum bypass current, A 5
Output characteristics
Crest factor 3:1
Maximum output current, A 2,3
Output power factor 0,8
Output voltage type single-phase
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50 (default)/ 60
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2.5 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 96
Efficiency in battery mode, % 81
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,2
Overload capacity (when operating in on-line mode or from batteries) 101-105% – for 3 min, 105-130% – for 60 s, 130-150% – for 1 s, above 150% – for 0.2 s (followed by switching to bypass)
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 7
Overload capacity (when operating via bypass or in ECO mode) 200% for 40 s
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0.5 s), overload and UPS fault (continuous)
Ethernet option (monitoring card required)
LCD display display of system operating status and main input and output parameters
LED indication status, mains, bypass, inverter, batteries
RS-485 option (monitoring card required, data exchange only with SHTYL equipment)
Indication type LCD display and LED indication
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys "On", "Off", "Up", "Enter"
USB option (monitoring card required)
Temperature sensor option (IC-SNMP/mini-USB monitoring card required)
Connection
Input mains IEC-320-C14
Load (output sockets) IEC-320-C13 (3 pcs.)
Priority disconnection of non-priority load no
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years at least 10
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour black
Weight, kg 15
Rack mounting height, U 2
Overall dimensions HxWxD (unpacked), mm 89x440x474 (rack, excluding brackets for horizontal mounting) 89x482x474 (rack, full dimensions) 467x207x474 (floor-standing)
Overall dimensions HxWxD (packed), mm 135x540x490
Batteries (battery packs)
Battery availability built-in
Hot-swap of built-in batteries yes
Battery runtime (at 80% UPS load) 12 min
Battery runtime at 100% (50%) UPS load, min 10 (22)
Internal battery capacity, Ah 9
Number of built-in 12 V batteries, pcs. 2
Rated battery voltage, V 24
Battery type sealed, maintenance-free, lead-acid
Battery service life, years up to 7 (depending on operating conditions)
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A 1
Built-in battery charge time, h no more than 8 (up to 90% capacity)

Write to us

We will reply to info@levrus.ru shortly