The STR300SL online UPS in floor/rack design will provide uninterrupted, high-quality power to critical loads with a total capacity of up to 300 VA/225 W, for example:
- network equipment;
- video surveillance systems;
- emergency signalling;
- smart home control units;
- low-power household appliances.
The STR300SL functions effectively in conjunction with a generator thanks to the improved operating algorithm of the power factor corrector.
Model STR300SL operates on the basis of double conversion technology, thanks to which:
- stabilises the voltage in the 90-295 V range with high accuracy (±2%) without switching to the batteries;
- provides an instantaneous and seamless transfer of the load to the battery in the event of a mains failure;
- supplies the load with a voltage with an ideal sine wave in any operating mode.
The device is equipped with a low-noise fan with automatic speed control.
Installation and connection
The STR300SL has a housing designed for two installation methods: floor-standing in a vertical position and in a 19-inch rack in a horizontal position (for this option, if the UPS is not placed on a shelf, it is recommended to additionally purchase a rack-mounting kit).
To connect the load, the UPS provides a block of three "computer" C13 sockets. The device is connected to the mains using a 1.5 m mains cable with a Euro plug.
Control panel
The STR300SL control panel is equipped with function buttons and three LED indicators:
- "Status" – device operating mode and occurrence of alarms;
- "Bypass" – operation via bypass/ECO mode;
- "Battery" – battery status.
The function buttons allow you to switch the device on/off, perform a cold start, change the operating mode (online, bypass or ECO), and test the battery (10-second forced battery-powered supply to the load). The test is started by holding the Mode Change button for 3 seconds.
Attention! Battery testing is recommended at least once every six months.
Battery operation
The STR300SL provides battery operation of the load by means of one built-in 9 Ah battery located in the battery block and a charger with a current of 1 A. At 100% load, the backup power supply to consumers will be 8 minutes (Battery runtime table).
Attention! The internal battery block is initially not connected to the UPS. This is done to prevent self-discharge of its battery. Before the first start-up of the device, the connector in the battery compartment must be connected. For more details, see the operation manual.
The UPS uses modern technologies to reduce charging time and extend battery life (intelligent charging and charge temperature compensation), as well as algorithms that allow:
- disconnect the battery at 80-85% discharge (protection against deep discharge);
- notify the user of battery wear;
- predict the autonomy time at the current load (the value is displayed in the device web interface; a monitoring card is required for connection).
Monitoring and configuration tools
- RS-232 (Megatec protocol);
- RS-485 (SHTYL protocol);
- USB and mini-USB;
- Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
- "dry" contacts;
- temperature sensor.
The status of the STR300SL UPS can be monitored in a web browser or in the Shtyl Device Manager (SDM) program. Editing the UPS parameters (start-up and operating mode, output voltage, rated output frequency when operating from the battery, bypass mode, on/off of the audible alarm, battery parameters, battery tests) is performed only via the "Settings" menu of the Shtyl Device Manager program when the computer is locally connected to the UPS via the USB interface or the RS-232 interface.
To remotely view the UPS status in a web browser, the device must be connected to the internet via an Ethernet connector. To set up such a connection, an IC-SNMP/Web or IC-SNMP/mini-USB interface expansion card is required.
Please note! The monitoring card is not included in the scope of supply and must be purchased separately.
Protection
The STR300SL features several types of electronic protection:
- against overload;
- against short circuit;
- against internal overheating.
Automatic restart is supported after the cause of the protection trip has been eliminated.
The UPS also features:
- mains protection against high-frequency interference – 150 kHz - 30 MHz;
- load protection against mains interference (between phase and neutral) – up to 2.5 kHz;
- emergency protection against operational faults (when it trips, the device de-energises the load or transfers its power supply to the mains without interruption via the bypass).
The STR300SL online UPS from the SHTYL brand offers an excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.