SHTYL STR1110SL online UPS (10 kVA / 8 kW)

  • Brand: Shtil
  • Product Code: STR1110SL
  • Availability: Pre-order
254 800 ₽

The STR1110SL online UPS in floor/rack (rack/tower) design is intended to provide backup power and protection against unstable voltage for equipment with a total power consumption of up to 10 kVA / 8 kW. Examples of loads include:

  • server and network devices;
  • computer equipment;
  • APCS;
  • security and video surveillance systems;
  • public address and emergency lighting systems.

The advanced power factor corrector algorithm enables the UPS to operate correctly with diesel/petrol generators.

STR1110SL with double conversion technology is capable of protecting against all types of power supply interruptions. Thanks to this operating principle, the device performs:

  • signal adjustment over a wide range (90-310 V) to autonomous mode;
  • instantaneous and seamless mode switching – transfer of power to the mains/batteries;
  • power supply to the load with voltage accuracy of ±2% and an ideal sine wave.

Installation and connection

The UPS has a universal (rack/tower) form factor. It can be installed on the floor or in 19-inch rails of racks and cabinets. When placing in a rack without shelves, it is recommended to purchase a mounting kit to support the product along its entire depth.

To connect the load, the STR1110SL rear panel provides several connectors: eight C13 sockets, two C19 sockets and terminals (L, N). The input mains is connected via terminal outputs (L, N, PE). A cable with a conductor cross-section of 10 mm2 is used for connection.

Battery operation

The UPS has two built-in battery blocks with batteries of a total capacity of 9 Ah and a 4 A charger. At 70% UPS load, consumers will be provided with autonomous power for 2 minutes. To increase the backup power time, external batteries can be connected to the UPS. The autonomous operation time from the built-in batteries at various load levels of the power supply is presented on the Autonomous operation tab.

In the event of failure of the built-in battery blocks, hot-swap replacement is provided, which will not affect the warranty.

Attention! Initially, the battery blocks are not connected to the UPS. This is done to prevent their self-discharge. Therefore, before the first switching on, it is necessary to install the battery blocks in the device housing, connecting the corresponding connectors. Read more about this in the operating manual.

The STR1110SL uses modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the batteries to be disconnected at 80-85% discharge (protection against «deep» discharge), notify the user of battery wear and predict the autonomy time at the current load.

Control panel

The UPS is equipped with a modern LCD display with a gyroscope that automatically changes its orientation depending on the position of the device's enclosure.

Information on the LCD display:

  • input voltage and input frequency values;
  • output voltage and output frequency values;
  • UPS load percentage relative to the rated output power;
  • active and apparent power;
  • mimic diagram showing the UPS status;
  • battery temperature, voltage and current;
  • internal temperature of the device;
  • battery charge level and predicted autonomy time;
  • alarm notification indicating the cause;
  • operating modes: online, bypass or battery power;
  • audible alarm status.

Configuring the main UPS operating parameters:

  • operating mode (on-line or ECO);
  • bypass mode (auto, on or off);
  • start method (auto or by button);
  • output voltage (220-240 V, in 5 V steps);
  • nominal output frequency when operating from the battery(50/60 Hz);
  • the battery charge level at which the non-priority load is switched off (from 10 to 90% in 5% steps);
  • the deep discharge level of the batteries.

Starting three types of battery test:

  • 10-second (load supply for 10 seconds);
  • for a specified time (powering the load for a specified time);
  • to full discharge (powering the load until the battery is fully discharged, measuring the residual capacity).

Battery tests are started and configured via the Commands menu, Battery Tests item.

Cooling system

The cooling system consists of two low-noise fans whose speed depends on the load level.

Protection

The STR1110SL UPS uses electronic protection against:

  • overload;
  • short circuit;
  • internal overheating.

Once the cause of the electronic protection activation is eliminated, the device restarts.

In addition, the UPS provides protection against high-frequency mains interference and surge voltages, as well as emergency protection against faults (if faults occur, the load is de-energised or switched without interruption to the mains via the bypass).

Monitoring tools

For remote monitoring of STR1110SL operation, its rear panel provides two slots for installing interface expansion cards:

  • RS-232 (Megatec protocol);
  • RS-485 (Modbus RTU/SHTYL protocols);
  • USB and mini-USB;
  • Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
  • "dry" contacts.

The status of the UPS and the load connected to it is monitored in a web browser or via the Shtyl Device Manager (SDM) software. The boards are not included in the basic scope of supply and are purchased additionally.

  • Advantages

General specifications
Apparent power, kVA 10
Active power, kW 8
Form factor floor-standing/rack-mount
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Maximum input current, A 55
Operating input voltage range, V 165-310 at 100% load135-310 at 80% load90-310 at 60% load
Rated input frequency, Hz 50
Rated input voltage, V 220
Soft start yes
Permissible input frequency range, Hz 43-57
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -5, -10, -15, -20, -25 (default: -20)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +20)
Limiting phase/line input voltage range, V 90-310 V
Output characteristics
Crest factor 3:1
Maximum output current, A 45
Output power factor 0,9
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50/60
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 95
Efficiency in battery mode, % 94
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,2
Overload capacity (when operating in on-line mode or from batteries) 101-105% – no time limit, 105-150% – for 5 s, above 150% – less than 5 s
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 7
Output mains type single-phase
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0,5 s), overload and UPS fault (continuous)
Ethernet option (monitoring card required)
RS-485 option (monitoring card required)
Indication type LCD display
EPO pluggable screw terminal block, wire cross-section: 0.08-1.2 mm².
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys switching between screens displayed on the LCD, UPS configuration
USB option (monitoring card required)
Rotating LCD display with built-in gyroscope display of system operating status and main input and output parameters
Connection
Input mains terminals (L, N, PE), conductor cross-section – 10 mm2
Load (output sockets) IEC-320-C13 (8 pcs.)IEC-320-C19 (2 pcs.)terminals (L, N), wire cross-section – according to power
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years 10
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour black
Weight, kg 78
Rack mounting height, U 4
Overall dimensions HxWxD (unpacked), mm 176x483x691 (rack)446x295x691 (floor-standing)
Batteries (battery packs)
Battery availability built-in and external (optional)
Hot-swap of built-in batteries yes
Battery runtime (at 80% UPS load) Depends on the external battery capacity
Internal battery capacity, Ah 9
Rated battery voltage, V 192
Battery type sealed, maintenance-free, lead-acid
Battery service life, years up to 7 (depending on operating conditions)
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A 4
Built-in battery charge time, h no more than 8 (up to 90% capacity)
Number of embedded 12 V batteries, pcs. 16