The STR1103TLD online UPS in universal design is intended to provide uninterrupted, high-quality power to a wide range of devices with a total capacity of up to 3000 VA / 2700 W, for example:
- server rooms, computer rooms and data centres;
- network equipment and telecommunications hardware;
- security, alarm and video surveillance systems;
- instrumentation and process control system devices.
Thanks to the improved power factor corrector operating algorithm, the STR1103TLD model functions excellently in conjunction with diesel generator sets.
STR1103TLD is a UPS with double conversion technology, thanks to which the device enables:
- stabilise the input voltage over a wide range (90-295 V) and with high accuracy (±2%) without switching to battery;
- instantly and seamlessly switch the load power to the battery when the mains voltage fails;
- supply the load with a perfect sinusoidal voltage.
Installation and connection
STR1103TLD can be installed in two ways: vertically on any flat horizontal surface (on the feet for vertical installation), horizontally in the 19-inch rails of telecommunications cabinets or racks. Mounting parts for both methods are included in the device's scope of supply.
To connect electrical equipment, the UPS has the following connectors: eight "computer" C13 sockets and terminal blocks. Connection to the input mains is made via outputs (L, N, PE).
Attention! The load connection sockets are segmented into primary and non-priority. When the UPS operates from the battery, a drop in the battery charge level to 20% (this value can be changed in the menu settings) will de-energise the non-priority sockets. The primary output sockets remain powered right up to a 'deep' battery discharge.
Battery operation
The UPS has a built-in charger (current 8 A) and the ability to connect external lead-acid batteries, which provide the required load backup time (Backup Time Table).
Depending on the required battery runtime, external batteries can be installed both in battery modules and in battery racks.
The UPS employs special technologies aimed at reducing charging time and extending battery service life:
- intelligent battery charging algorithm (charging is first performed in cyclic mode (elevated voltage), then in float mode (standby voltage));
- battery charge temperature compensation (automatic adjustment of charge voltage depending on battery temperature).
In addition, the UPS features special algorithms that allow the battery to be disconnected at 80-85% discharge (protection against deep discharge), notify the user in advance of battery wear, and accurately predict the autonomy time at the current load.
Control panel
STR1103TLD has a modern digital LCD display with a built-in gyroscope, thanks to which the UPS automatically changes the screen orientation depending on the position of the device.
Information on the LCD display:
- input voltage and input frequency values;
- output voltage and output frequency values;
- UPS load percentage relative to the rated output power;
- active and apparent power;
- mimic diagram showing the UPS status;
- battery temperature, voltage and current;
- internal temperature of the device;
- battery charge level and predicted autonomy time;
- alarm notification indicating the cause;
- operating modes: online, bypass or battery power;
- audible alarm status.
Configuring the main UPS operating parameters:
- operating mode (on-line or ECO);
- bypass mode (auto, on or off);
- start method (auto or by button);
- output voltage (220, 230 or 240 V);
- nominal output frequency (50/60 Hz);
- the battery charge level at which the non-priority load is switched off (from 10 to 90% in 5% steps);
- the deep discharge level of the batteries.
Starting three types of battery test:
- 10-second (the UPS supplies the load from the battery for 10 seconds);
- for a specified time (the UPS powers the load from the battery for a specified time);
- to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).
Battery tests are started and configured via the Commands menu, Battery Tests item.
Cooling system
The device is equipped with a low-noise fan with automatic speed control.
Protection
The STR1103TLD features electronic protection against:
- overload;
- short circuit;
- internal overheating.
The device is able to automatically resume operation once the cause of the protection tripping has been eliminated.
In addition, the UPS incorporates protection against high-frequency mains interference and surge voltages, as well as emergency protection against operational faults (when it triggers, the consumers are disconnected or transferred to the mains via bypass without interruption).
Monitoring tools
STR1103TLD offers extensive capabilities for organising local/remote monitoring and control of operation. For this purpose, expansion cards with the following interfaces are connected to the UPS:
- RS-232 (Megatec protocol);
- RS-485 (Modbus RTU/SHTYL protocols);
- USB and mini-USB;
- Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
- "dry" contacts.
The operation of the UPS with an installed card can be monitored directly in a web browser or in the Shtyl Device Manager (SDM) software. Please note that the cards are not included in the standard scope of supply and are purchased separately.
Excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.
- Advantages