Single-phase UPS

SHTYL STR1103L UPS kit (3 kVA / 2.7 kW) with battery for 1.5 h

  • Brand: Shtil
  • Product Code: STR1103L-72Ah
  • Availability: Pre-order
309 700 ₽

The kit consists of an STR1103L online UPS with a capacity of 3 kVA / 2,7 kW and four BMRT-72-18 battery modules with a total battery capacity of 72 Ah. The solution is suitable for uninterruptible power supply and protection against voltage fluctuations for a server, computer, network equipment and video surveillance system.

Thanks to the improved power factor corrector operating algorithm, the UPS functions excellently in conjunction with diesel generator sets.

UPS with double conversion technology, by means of which the following is performed:

  • voltage correction over the range 90-295 V without switching to battery;
  • instant switching to autonomous mode when the power fails;
  • continuous power supply to equipment with voltage accuracy of ±2% and a pure sine wave.

Installation and connection

The UPS and the battery module are installed vertically on the floor/shelving or horizontally in the 19-inch rails of telecommunications cabinets or racks. Mounting parts for both methods are included.

To connect electrical equipment, the UPS has the following connectors: 8 "computer" C13 sockets and one C19 socket. Connection to the input mains is made via the C20 connector.

Attention! The load connection sockets are segmented into primary and non-priority. When the UPS operates from the battery, a drop in the battery charge level to 20% (this value can be changed in the menu settings) will de-energise the non-priority sockets. The primary output sockets remain powered right up to a 'deep' battery discharge.

Battery operation

The UPS is equipped with a built-in charger with a current of 4 A. Backup power for the equipment is provided by 18 Ah battery modules containing two battery blocks BP-72-09/RT. Each block contains six 12 V batteries of 9 Ah each.

At 80% UPS load, consumers will be provided with autonomous power for 1.5 h. The battery runtime at other load levels is shown on the Battery runtime tab.

In the event of failure of the built-in batteries, hot-swap replacement is provided. Battery replacement does not affect the warranty.

Attention! The internal battery blocks in the module are initially disconnected. This is done to prevent their self-discharge. Therefore, before the first start-up of the device, the connector in the battery compartment must be connected. For more details, see the operation manual.

The UPS employs modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against deep discharge), notify the user of battery wear and predict autonomy time.

Control panel

The UPS features an LCD display with a built-in gyroscope, which automatically changes the screen orientation depending on the device position.

Information on the LCD display:

  • input/output voltage and input/output frequency values;
  • UPS load percentage relative to the rated output power;
  • active and apparent power;
  • mimic diagram showing the UPS status;
  • battery temperature, voltage and current;
  • internal temperature of the device;
  • battery charge level and predicted autonomy time;
  • alarm notification indicating the cause;
  • operating modes: online, bypass or battery power;
  • audible alarm status.

Configuring the main UPS operating parameters:

  • operating mode (on-line or ECO) and bypass (auto, on or off);
  • start method (auto or by button);
  • output voltage (220, 230 or 240 V);
  • nominal output frequency (50/60 Hz);
  • the battery charge level at which the non-priority load is switched off (from 10 to 90% in 5% steps);
  • the deep discharge level of the batteries.

Starting three types of battery test:

  • 10-second (the UPS supplies the load from the battery for 10 seconds);
  • for a specified time (the UPS powers the load from the battery for a specified time);
  • to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).

Protection

The UPS features modern electronic protection against overload, short circuit and internal overheating. Automatic restart of the UPS is supported after the cause of the protection trip has been eliminated.

The device is provided with mains protection against high-frequency interference (150 kHz - 30 MHz), load protection against mains interference (between phase and neutral, up to 2.5 kHz) and emergency protection against operational faults.

Cooling system

The device is equipped with a low-noise fan with automatic speed control.

Monitoring tools

The UPS provides local/remote status monitoring. The function is implemented using cards, which can have different interfaces: RS-232 (Megatec protocol), RS-485 (Modbus RTU / SHTYL protocols), USB, mini-USB, Ethernet (Web / SNMP / NTP / Modbus TCP / SHTYL protocols) and dry contacts. The cards are not included in the standard scope of supply and are purchased separately.

The operation of the UPS with an installed card can be monitored directly in a web browser or in the Shtyl Device Manager (SDM) software.

The kit with the STR1103L UPS offers an excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.

  • Advantages

General specifications
Apparent power, kVA 3
Active power, kW 2,7
Form factor floor-standing/rack-mount
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Country of manufacture Russia
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Input power factor 0,99
Limiting input voltage range, V 90-295
Maximum input current, A 15
Operating input voltage range, V 175-295 at 100% load, 155-295 at 75% load, 120-295 at 50% load
Power consumption in no-load mode, W 40
Rated input frequency, Hz 50
Rated input voltage, V 220
Soft start yes
Permissible input frequency range, Hz 45-65
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -5, -10, -15, -20, -25 (default: -20)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +20)
Output characteristics
Crest factor 3:1
Maximum output current, A 9
Output power factor 0,9
Output voltage type single-phase
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50/60
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2.5 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 95
Efficiency in battery mode, % 86
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,2
Overload capacity (when operating in on-line mode or from batteries) 101-105% – no time limit, 105-130% – for 60 s, 130-150% – for 1 s, above 150% – for 0.2 s (followed by switching to bypass)
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 7
Overload capacity (when operating via bypass or in ECO mode) 200% for 40 s
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0,5 s), overload and UPS fault (continuous)
Ethernet option (monitoring card required)
RS-485 option (monitoring card required)
Indication type LCD display
EPO pluggable screw terminal block, wire cross-section: 0.08-1.2 mm².
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys switching between screens displayed on the LCD, UPS configuration
USB option (monitoring card required)
Rotating LCD display with built-in gyroscope display of system operating status and main input and output parameters
Connection
Priority disconnection of non-priority load yes
The charge level at which the non-priority load is disconnected user-settable (default – 20%)
Cable entry IEC-320-C13 (8 pcs.), IEC-320-C19 (1 pc.)
Bypass input IEC-320-C20
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years at least 10
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour black
Weight, kg 193 (9 UPS, 46 x 4 battery modules)
Rack mounting height, U 10 (2 UPS, 2 x 4 battery module)
Overall dimensions HxWxD (unpacked), mm UPS – 88x482x447 (rack), 466x207x447 (floor)Battery module – 89x499x545 (rack), 469x207x545 (floor)
Overall dimensions HxWxD (packed), mm UPS – 135x490x540, battery module – 590x490x125
Batteries (battery packs)
Battery availability external
Hot-swap of built-in batteries yes
Battery runtime (at 80% UPS load) 1.5 h
Rated battery voltage, V 72
Battery type sealed, maintenance-free, lead-acid
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A 4