SHTYL ST3115L online UPS (15 kVA / 12 kW)

  • Brand: Shtil
  • Product Code: ST3115L
  • Availability: Pre-order
334 900 ₽

The ST3115L online UPS with three-phase input and single-phase output is designed to provide uninterrupted power supply and protection against voltage fluctuations in a 380 V network for commercial and industrial equipment with a total power of up to 15 kVA /12 kW, for example:

  • server rooms, computer rooms and data centres;
  • telecommunications equipment and communication systems;
  • machine-tool and conveyor equipment;
  • video surveillance and security systems.

Thanks to the 3-in-1 configuration, the UPS allows a single-phase load to be connected to a three-phase mains (while the power of the connected devices may be greater than the power of an individual phase) with even loading of all supply phases, which eliminates the possibility of mains imbalance and removes the need for constant inter-phase balancing.

ST3115L is an online UPS with high-frequency double voltage conversion, thanks to which the device allows:

  • stabilise the input voltage over a wide range (phase voltage – 90-295 V) without switching to autonomous mode;
  • instantly and seamlessly switch the load power to the battery when the mains voltage fails;
  • supply the load with a perfect sinusoidal voltage with high stabilisation accuracy (±2%).

Thanks to the improved power factor corrector operating algorithm, the ST3115L model functions excellently in conjunction with diesel generator sets.

Installation and connection

The UPS has a floor-standing (tower) design, which involves installing the device on any flat horizontal surface on swivel castors.

The load and input mains are connected via terminal connections.

Battery operation

To provide autonomous operation of the load, the UPS includes a built-in charger (current 5 A) and a connector for connecting external batteries. The maximum capacity of external batteries is 150 Ah, which provides autonomous operation for 1 h at 100% load (Battery Runtime Table).

External batteries are installed in dedicated battery modules or racks.

The ST3115L uses modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation).

In addition, the model features special algorithms that allow:

  • disconnect the battery at 80-85% discharge (protection against deep discharge);
  • notify the user in advance of battery wear;
  • accurately predict the autonomy time at the current load.

Control panel

The main operating parameters of the UPS are monitored and configured using the control panel. It includes an LCD display, function keys and five LED indicators:

  • "Fault" – a fault has occurred in the device operation;
  • "Mains" – input mains normal, UPS in normal (online) operation;
  • "Bypass" – a switch to bypass has been performed;
  • "Output" – voltage is supplied to the load;
  • "Battery" – battery status.

Information on the LCD display:

  • input and output voltage values;
  • UPS load percentage;
  • input mains and output frequency;
  • battery voltage values;
  • active and apparent load power;
  • output status;
  • alarms with indication of causes.

The control panel allows three battery tests to be performed:

  • 10-second (the UPS supplies the load from the battery for 10 seconds);
  • for a specified time (the UPS powers the load from the battery for a specified time);
  • to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).

Tests are started via the System menu, UPS Command item.

Protection

ST3115L is equipped with modern electronic protection against:

  • output overload;
  • short circuit;
  • internal overheating.

Once the cause of the protection activation is eliminated, the UPS automatically restarts.

In addition, the model has protection against high-frequency mains interference and surge voltages, as well as emergency protection against faults (if it triggers, the connected load is either disconnected or transferred to the mains via bypass).

Monitoring tools

For local configuration and monitoring, the ST3115L model uses the RS232 interface.

For additional remote/local monitoring, the rear panel of the enclosure provides a slot allowing installation of an expansion card with the following interfaces:

  • Ethernet;
  • "dry" contacts.

Please note that the expansion board is not included in the standard scope of supply and must be purchased separately.

Excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.

  • Advantages

General specifications
Apparent power, kVA 15
Active power, kW 12
Form factor floor-standing
Number of phases 3-in-1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Input characteristics
Generator compatibility yes
Input mains type three-phase five-wire with common neutral (L1, L2, L3, N, PE)
Input power factor 0,99
Maximum input current per phase, A 30
Rated input frequency, Hz 50/60
Soft start yes
Permissible input frequency range, Hz 43-57
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -20%, setting step – 1 V, default: -10%
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +20%, setting step – 1 V, default: +10%
Limiting phase/line input voltage range, V 90-295/155-510
Operating phase/line input voltage range, V 160-275/275-475 at 100% load, 135-160/235-275 at 75% load, 90-135/155-235 at 50% load
Rated phase-to-neutral/phase-to-phase input voltage, V 220/380
Output characteristics
Crest factor 3:1
Maximum output current, A 67
Output power factor 0,8
Output voltage type single-phase
Rated output frequency, Hz 50/60
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 95
Efficiency in battery mode, % 94
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,1
Overload capacity (when operating in on-line mode or from batteries) 105-130% – for 600 s, 130-150% – for 60 s, above 150% – for 1 s (followed by switching to bypass)
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 5
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Control panel and interfaces
Ethernet option (monitoring card required)
LCD display display of system operating status and main input and output parameters
Indication type LCD display and LED indication
"Dry" contacts option (monitoring card required)
RS-232 in basic configuration
Function keys control of the menu displayed on the LCD, UPS configuration
Separate electronic bypass input yes
Connection
Input mains terminal connection (L1, L2, L3, N, PE)
Load (output sockets) terminal connection (L, N, PE)
Bypass input terminal connection (L)
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 1000 m above sea level
Relative humidity, % from 0 to 95 (non-condensing)
Service life, years at least 10
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour grey
Weight, kg 40
Overall dimensions HxWxD (unpacked), mm 585×255×565
Batteries (battery packs)
Battery availability external (option)
Battery runtime (at 80% UPS load) Depends on the external battery capacity
Rated battery voltage, V 192
Battery type sealed, maintenance-free, lead-acid
Battery service life, years up to 7 (depending on operating conditions)
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A 5