The ST3110L online UPS with three-phase input and single-phase output serves to provide uninterrupted power supply and protection against voltage fluctuations in a 380 V network for critical single-phase electrical appliances with a total power of up to 10 kVA /8 kW, for example:
- of expensive household appliances;
- servers, small data centres and computer rooms;
- IT infrastructure of offices and network equipment;
- telecommunications equipment and communication systems;
- security, intruder and alarm systems.
Thanks to its 3-in-1 configuration, the ST3110L UPS allows a single-phase load to be connected to a three-phase network (while the capacity of the connected appliances may be greater than the capacity of an individual phase) with even loading of all supply phases, which eliminates the possibility of network imbalance and removes the need for constant inter-phase balancing.
ST3110L is an online UPS with high-frequency double energy conversion, thanks to which the device allows:
- stabilise the input voltage over a wide range (phase voltage – 90-295 V) without switching to autonomous mode;
- instantly and seamlessly switch the load power to the battery when the mains voltage fails;
- supply the load with a perfect sinusoidal voltage with high stabilisation accuracy (±2%).
Thanks to the improved power factor corrector operating algorithm, the ST3110L model functions excellently in conjunction with diesel generator sets.
Installation and connection
The UPS has a floor-standing (tower) design – the device is installed on any flat horizontal surface.
The load and the device's power supply are connected via terminal blocks located on the rear of the enclosure.
Battery operation
To provide autonomous operation, the UPS has a built-in charger (current from 1 to 4, setting step 0.5 A) and a connector for connecting external batteries. The maximum capacity of external batteries is 120 Ah (without an external charger) and 150 Ah (with an external charger), which will provide autonomous operation for 1 h or 1.5 h respectively (at 100% load) (Autonomy Time Table).
Batteries are installed in dedicated battery modules or racks. Our sales department specialists will always help you choose the optimal solution for battery capacity and placement.
The ST3110L uses modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against «deep» discharge), notify the user of battery wear and predict the autonomy time at the current load.
Control panel
The main operating parameters of the UPS are monitored and configured using the control panel. It includes an LCD display, four function keys and five LED indicators:
- "Fault" – a fault has occurred in the device operation;
- "Mains" – input mains normal, UPS in normal (online) operation;
- "Bypass" – a switch to bypass has been performed;
- "Output" – voltage is supplied to the load;
- "Battery" – battery status.
Information on the LCD display:
- input and output voltage values;
- UPS load percentage;
- input mains and output frequency;
- battery voltage values;
- active and apparent load power;
- output status and alarms with causes indicated.
The control panel allows three battery tests to be performed:
- 10-second (the UPS supplies the load from the battery for 10 seconds);
- for a specified time (the UPS powers the load from the battery for a specified time);
- to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).
Tests are started via the System menu, UPS Command item.
Protection
ST3110L is equipped with modern electronic protection against:
- overload;
- short circuit;
- internal overheating.
The UPS will restart automatically once the cause of the protection trip has been eliminated.
The device also features:
- mains protection against high-frequency interference – 150 kHz - 30 MHz;
- load protection against mains interference (between phase and neutral) – up to 2.5 kHz;
- emergency protection against any faults (when it trips, the consumers are switched off or transferred to the mains without interruption via the bypass).
Using a separate input for the automatic electronic bypass prevents load imbalance on one of the supply phases when operating in bypass mode.
Monitoring tools
The ST3110L model provides local/remote operation monitoring. On the rear panel of the device there are several slots for installing expansion cards with the following interfaces:
- RS-232 (Megatec protocol);
- RS-485 (Modbus RTU/SHTYL protocols);
- USB and mini-USB;
- Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
- "dry" contacts.
UPS operation with an installed card can be tracked in a web browser or via the dedicated Shtyl Device Manager (SDM) software.
Please note that expansion boards are not included in the standard scope of supply and must be purchased separately.
Excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.
- Advantages