The ST1110L online UPS is used to ensure uninterrupted operation and individual/group protection against unstable mains voltage for single-phase electrical appliances with a total power of 10 kVA /8 kW, for example:

  • gas and water-heating boilers and auxiliary equipment;
  • audio equipment and video equipment;
  • server rooms and small data centres;
  • network equipment;
  • security and alarm systems;
  • video surveillance systems.

Thanks to the improved power factor corrector operating algorithm, the ST1110L model functions excellently in conjunction with diesel generator sets.

ST1110L is an online UPS with high-frequency double energy conversion, thanks to which the device allows:

  • stabilise the input voltage over a wide range (90-310 V) without switching to autonomous mode
  • instantly and seamlessly switch the load power to the battery when the mains voltage fails
  • supply the load with a perfect sinusoidal voltage with high stabilisation accuracy (±2%).

The device is cooled by two low-noise fans with an intelligent operating principle.

Control panel

The main operating parameters of the UPS are monitored and configured using the control panel. It includes an LCD display, four function keys and five LED indicators:

  • "Status" – indicates the device operating mode;
  • "Mains" – indicates mains status;
  • "Bypass" – indicates a switch to bypass/ECO mode;
  • "Inverter" – indicates inverter operation;
  • "Battery" – shows the battery status.

Information on the display:

  • input and output voltage values;
  • UPS load percentage;
  • battery voltage values and their status;
  • active and apparent load power;
  • alarms with indication of their causes.

The control panel allows three battery tests to be performed:

  • 10-second (the UPS supplies the load from the battery for 10 seconds);
  • for a specified time (the UPS powers the load from the battery for a specified time);
  • to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).

Battery tests are started and configured via the Commands menu, Battery Tests item.

Installation and connection

The UPS is designed for floor installation (tower) on any flat horizontal surface.

To connect the load and connect to the input mains, terminal blocks are used, located on the device rear panel in a special closed compartment.

Battery operation

To provide autonomous operation of the load, the ST1110L has a built-in charger (current from 1 to 4 A, setting step – 0.5 A) and a connector for connecting external batteries. The maximum capacity of external batteries is 120 Ah (without installing an external charger) and 150 Ah (with an external charger), which will provide autonomous operation for 1 h or 1.5 h respectively (at 100% load) (Battery runtime table).

Batteries are installed in dedicated battery modules or racks.

The ST1110L uses modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against «deep» discharge), notify the user of battery wear and predict the autonomy time at the current load.

Protection

ST1110SL is equipped with electronic protection against:

  • output overload;
  • short circuit;
  • internal overheating.

Once the cause of the electronic protection activation is eliminated, the device restarts automatically.

In addition, the UPS provides protection against high-frequency mains interference and surge voltages, as well as emergency protection against any faults (if they occur, the device disconnects the load or transfers its power to the mains via the bypass).

Monitoring tools

For local/remote monitoring of ST1110L UPS operation, several expansion cards must be installed, which may contain the following interfaces:

  • RS-232 (Megatec protocol);
  • RS-485 (Modbus RTU/SHTYL protocols);
  • USB and mini-USB;
  • Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
  • "dry" contacts.

UPS operation with an installed card can be monitored via a web browser or the dedicated Shtyl Device Manager (SDM) software. Expansion cards are not included in the scope of supply and are purchased separately.

Excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.

  • Advantages

General specifications
Apparent power, kVA 10
Active power, kW 8
Form factor floor-standing
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Country of manufacture Russia
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Input power factor 0,99
Limiting input voltage range, V 90-310
Maximum input current, A 55
Operating input voltage range, V 165-310 at 100% load, 135-310 at 80% load, 90-310 at 60% load
Rated input frequency, Hz 50
Rated input voltage, V 220
Soft start yes
Permissible input frequency range, Hz 43-57
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -5, -10, -15, -20, -25 (default: -20)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +20)
Output characteristics
Crest factor 3:1
Maximum output current, A 45
Output power factor 0,8
Output voltage type single-phase
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50/60
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 95
Efficiency in battery mode, % 94
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,1
Overload capacity (when operating in on-line mode or from batteries) less than 105% – unlimited, 105-150% – at least 5 s, more than 150% – no more than 5 s (followed by switching to bypass)
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 5
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode, low voltage of internal and/or external batteries, battery disconnected/fully discharged/needs replacement, overload and UPS fault
Ethernet option (monitoring card required)
LCD display display of system operating status and main input and output parameters
LED indication status, mains, bypass, inverter, battery
RS-485 option (monitoring card required)
Indication type LCD display and LED indication
EPO pluggable screw terminal block, wire cross-section: 0.08-1.2 mm².
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys control of the menu displayed on the LCD, UPS configuration
USB option (monitoring card required)
Connection
Input mains terminal connection (L, N, PE)
Load (output sockets) terminal connection (L, N, PE)
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years at least 10
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour grey
Weight, kg 18
Overall dimensions HxWxD (unpacked), mm 438x250x572
Overall dimensions HxWxD (packed), mm 615×300×485
Batteries (battery packs)
Battery availability external (option)
Hot-swap of built-in batteries no
Rated battery voltage, V 192
Battery type sealed, maintenance-free, lead-acid
Battery service life, years up to 7 (depending on operating conditions)
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A from 1 to 4 (setting step – 0.5 A)