The ST1103L online UPS ensures uninterrupted operation and stabilised power supply for a single-phase load with a power of 3 kVA/ 2.7 kW, for example:
- heating systems and heating equipment;
- computers and peripheral equipment;
- household appliances, including equipment with electric motors;
- retail and banking equipment;
- lighting systems;
- video surveillance and alarm systems.
Thanks to the improved power factor corrector operating algorithm, the ST1103L model functions excellently in conjunction with diesel generator sets.
ST1103L is an online UPS with double energy conversion, thanks to which the device allows:
- stabilise the input voltage over a wide range (90-295 V) without switching to battery;
- instantly and seamlessly switch the load power to the battery when the mains voltage fails;
- supply the load with a perfect sinusoidal voltage with high stabilisation accuracy (±2%).
Installation and connection
The ST1103L is placed on the floor on any flat horizontal surface.
To power the load, the UPS rear panel provides the following connectors: two Euro sockets, three "computer" C13 sockets and one C19 socket. The device is connected to the mains via the C20 connector.
Battery operation
ST1103L is equipped with a charger (current 2 A) and a dedicated connector for connecting external batteries (up to 40 Ah), which provide the required load autonomy time (up to 30 minutes at 100% load) (Autonomy Time Table).
External batteries are installed using battery modules or racks.
The SW250SL uses modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation).
In addition, the model features special algorithms that allow:
- disconnect the battery at 80-85% discharge (protection against deep discharge);
- notify the user in advance of battery wear;
- accurately predict the autonomy time at the current load.
Attention! If you purchase a UPS without an autonomous power solution from SHTYL Group (a battery module or a rack with batteries and a battery kit, see the Autonomous Operation tab), then to connect your own external batteries you will need to additionally purchase a TD50A battery cable (see the Accessories tab). It is not included in the basic UPS configuration!
Cooling system
The device is cooled by two low-noise fans with an adaptive operating mode.
Control panel
The main operating parameters of the ST1103L are monitored and configured using the control panel. It includes an LCD display, four function keys and five LED indicators:
- "Status" – indicates the device operating mode;
- "Mains" – indicates mains status;
- "Bypass" – indicates a switch to bypass/ECO mode;
- "Inverter" – indicates inverter operation;
- "Battery" – shows the battery status.
The LCD display shows the following information:
- input and output voltage values;
- UPS load percentage;
- battery voltage values and their status;
- active and apparent load power;
- alarms with indication of their causes.
The control panel allows three battery tests to be performed:
- 10-second (the UPS supplies the load from the battery for 10 seconds);
- for a specified time (the UPS powers the load from the battery for a specified time);
- to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).
Tests are started via the System menu, UPS Command item.
Protection
The ST1103L is equipped with electronic multi-level protection against:
- short circuit;
- sustained output overload;
- internal overheating.
The UPS recovers automatically once the cause of the electronic protection tripping has been eliminated.
In addition, the device is capable of protecting the load from mains interference and surge voltages (built-in varistor – 2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs). The UPS also has emergency protection against operational faults, when it triggers the load is either switched off or transferred to the mains via the built-in bypass without interruption.
Monitoring tools
Model ST1103L has special slots for installing monitoring cards with the following interfaces:
- RS-232 (Megatec protocol);
- RS-485 (Modbus RTU/SHTYL protocols);
- USB and mini-USB;
- Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
- "dry" contacts.
The UPS with an installed board is monitored in a web browser or in the Shtyl Device Manager (SDM) software.
The boards are not included in the standard scope of supply and are purchased separately.
Excellent price/quality ratio compared with similar products from foreign vendors on the Russian power supply systems market.
- Advantages