‎+7 (499) 500-24-60
Moscow, Udaltsova St., 81, bldg 2, office 6
Single-phase UPS

SHTYL ST1102L UPS kit (2 kVA / 1.8 kW) with battery for 20 min

  • Brand: Shtil
  • Product Code: ST1102L-18Ah
  • Availability: Pre-order
95 030 ₽

The kit consists of an ST1102L online UPS and a BMT-72-18 battery module. It provides backup power to a critical load for 20 minutes at 80% UPS load. It is used in offices, private houses or apartments for heating equipment, a computer, server or commercial equipment.

Thanks to the improved power factor corrector operating algorithm, the UPS functions in conjunction with diesel generator sets.

Cooled by low-noise fans with adaptive operation mode.

UPS with double conversion technology, thanks to which the device allows:

  • stabilise the voltage over the range 90-295 V without switching to battery;
  • instantly switch the load power to the battery when the mains fails;
  • supply the load with high-accuracy voltage (±2%) with a pure sine wave.

Installation and connection

The UPS and the battery module are in a floor-standing design and are installed on any flat horizontal surface on rubber feet.

To power the load, the UPS rear panel provides C13 connectors (3 pcs), earthed Euro sockets (2 pcs) and C19 (1 pc). The C20 connector is used for connecting the input AC voltage.

Battery operation

The UPS has a built-in 4 A charger. Autonomous operation of the load is provided by the battery module. It contains two groups of six 12 V batteries of 9 Ah each. Equipment will run for 20 minutes at 80% UPS load. The battery runtime from built-in and external batteries at other UPS load levels is shown on the Battery Runtime tab.

The UPS employs modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation).

In addition, the model features special algorithms that allow:

  • disconnect the battery at 80-85% discharge (protection against deep discharge);
  • notify the user in advance of battery wear;
  • accurately predict the autonomy time at the current load.

Control panel

The main operating parameters of the product are monitored and configured using the control panel. It includes an LCD display, four function keys and five LED indicators:

  • "Status" – indicates the device operating mode;
  • "Mains" – indicates mains status;
  • "Bypass" – indicates a switch to bypass/ECO mode;
  • "Inverter" – indicates inverter operation;
  • "Battery" – shows the battery status.

Information on the LCD display:

  • input and output voltage values;
  • UPS load percentage;
  • battery voltage values and their status;
  • active and apparent load power;
  • alarms with indication of their causes.

The control panel also allows three types of battery test to be performed:

  • 10-second (the UPS supplies the load from the battery for 10 seconds);
  • for a specified time (the UPS powers the load from the battery for a specified time);
  • to full discharge (the UPS powers the load from the battery until it is fully discharged, measuring the residual capacity).

Protection

The UPS has modern electronic protection against overload, short circuit and internal overheating. After the cause of the electronic protection tripping is eliminated, the UPS restarts automatically.

The device is protected against high-frequency mains interference and impulse overvoltages, as well as by emergency protection against operating faults.

Monitoring tools

The UPS supports local/remote operation monitoring. For this purpose, the rear panel of the device provides two slots for installing expansion cards, which may contain the following interfaces:

  • RS-232 (Megatec protocol);
  • RS-485 (Modbus RTU/SHTYL protocols);
  • USB and mini-USB;
  • Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
  • "dry" contacts.

UPS operation with an installed interface expansion card is conveniently monitored via a web browser or the Shtyl Device Manager (SDM) software. The cards are not included in the standard configuration and are purchased separately.

  • Advantages

General specifications
Apparent power, kVA 2
Active power, kW 1,8
Form factor floor-standing
Number of phases 1 to 1
Operating modes on-line, autonomous, bypass, ECO
Topology on-line (double conversion)
Country of manufacture Russia
Input characteristics
Generator compatibility yes
Input mains type single-phase three-wire (L, N, PE)
Input power factor 0,99
Limiting input voltage range, V 90-295
Maximum input current, A 15
Operating input voltage range, V 175-295 at 100% load, 155-295 at 75% load, 120-295 at 50% load
Power consumption in no-load mode, W 40
Rated input frequency, Hz 50
Rated input voltage, V 220
Soft start yes
Permissible input frequency range, Hz 45-65
Permissible deviation of the lower input voltage limit in ECO mode and for the electronic bypass, % -5, -10, -15, -20, -25 (default: -20)
Permissible deviation of the upper input voltage limit in ECO mode and for the electronic bypass, % +5, +10, +15, +20, +25 (default: +20)
Output characteristics
Crest factor 3:1
Maximum output current, A 9
Output power factor 0,9
Output voltage type single-phase
Rated output frequency, Hz when operating from the mains – matches the mains frequency; when operating from the battery – set by the user: 50/60 (default – 50)
Transfer time to battery mode from on-line mode, ms 0
Output voltage total harmonic distortion, % <2.5 with linear load, <4 with non-linear load
Rated AC output voltage, V 220
Output voltage waveform pure sine wave
Efficiency in online mode, % 95
Efficiency in battery mode, % 86
Output voltage stabilisation accuracy, % ±2
Output frequency stabilisation accuracy (when operating from battery), % ±0,2
Overload capacity (when operating in on-line mode or from batteries) 101-105% – no time limit, 105-130% – for 60 s, 130-150% – for 1 s, above 150% – for 0.2 s (followed by switching to bypass)
Efficiency in bypass or ECO mode, % 99
Transfer time to battery mode from ECO mode, ms 7
Overload capacity (when operating via bypass or in ECO mode) 200% for 40 s
Protection
Output overload electronic protection with auto-restart
Overheating electronic protection with auto-restart
Short circuit electronic protection with auto-restart
Protection against UPS failure electronic emergency protection
Protection against deep battery discharge yes
Electronic automatic bypass yes
Surge protection varistor (2 kV (case-to-wire), 1 kV (wire-to-wire), response – 50 µs)
Mains protection against high-frequency interference 150 kHz - 30 MHz
Load protection against mains interference (between phase and neutral) up to 2.5 kHz
Control panel and interfaces
Audible alarm battery mode (every 4 s), low battery voltage (every 2 s), battery disconnected/fully discharged/needs replacement (every 0,5 s), overload and UPS fault (continuous)
Ethernet option (monitoring card required)
LCD display display of system operating status and main input and output parameters
LED indication status, mains, bypass, inverter, batteries
RS-485 option (monitoring card required)
Indication type LCD display and LED indication
EPO two-contact screw terminal (terminal block), conductor cross-section: 0.08-1.2 mm².
"Dry" contacts option (monitoring card required)
mini-USB option (monitoring card required)
RS-232 option (monitoring card required)
Function keys control of the menu displayed on the LCD, UPS configuration
USB option (monitoring card required)
Connection
Input mains IEC-320-C20
Load (output sockets) IEC-320-C13 (3 pcs.), EURO F-type with grounding (2 pcs.), IEC-320-C19 (1 pc.)
Reliability and performance characteristics
Cooling type forced air cooling (fan)
Degree of protection against dust and moisture IP20
Installation indoor
Operating altitude, m up to 3000 m above sea level
Relative humidity, % from 0 to 80 (non-condensing)
Service life, years at least 10
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour grey
Weight, kg UPS – 14Battery module – 48
Overall dimensions HxWxD (unpacked), mm UPS – 346x210x443Battery module – 346x210x442
Overall dimensions HxWxD (packed), mm UPS – 395x260x505Battery module – 395x260x505
Batteries (battery packs)
Battery availability external
Hot-swap of built-in batteries no
Battery runtime (at 80% UPS load) 20 min
Battery runtime at 100% (50%) UPS load, min 15 (37)
Rated battery voltage, V 72
Battery type sealed, AGM technology
Battery service life, years up to 8
Battery management functionality residual capacity determination, tests (10-second, for a specified runtime, until full discharge), deep discharge protection, charge temperature compensation
Cold start yes
Rated charge current of the built-in charger, A 4
Built-in battery charge time, h no more than 8 (up to 90% capacity)

Write to us

We will reply to info@levrus.ru shortly