The SHTYL SR1101L online UPS kit with three external 105 Ah batteries housed in a TC-1801-01D2 telecommunications cabinet provides backup power to a critical load for 3 hours 40 min (at 80% load). The battery runtime at other UPS load levels is shown on the Battery runtime tab. Examples of connected load include a server, computer, telecommunications equipment or video surveillance system.
The UPS also protects connected equipment from voltage surges and electrical interference.
The power supply operates excellently in conjunction with a generator thanks to an improved power factor corrector algorithm.
The UPS operates on the principle of double conversion of electric current, which provides:
- voltage correction over a wide range (90-295 V) and without switching to battery;
- instant (seamless) switching to the battery when the power fails or the voltage goes outside the operating range;
- supplying equipment with high-accuracy voltage (±2%) with a pure sine wave.
Installation and connection
The kit is supplied partially assembled. The UPS, mounting kit, battery protection module and shelf are already pre-installed in the cabinet. You only need to place the batteries and connect them in accordance with the instructions. The connection cables are included in the scope of supply.
For load power supply, one Schuko socket and three C13 computer connectors are used. The UPS is connected to the mains via a C14 connector.
Protection
Protection against short circuits, prolonged output overload and internal overheating is provided. The device resumes operation automatically after the cause of the electronic protection tripping is eliminated.
The UPS also has protection against:
- impulse overvoltages (varistor – 2 kV ("case-wire"), 1 kV ("wire-wire"), response – 50 μs);
- operating faults (when the emergency protection trips, the consumers are disconnected or seamlessly switched to the mains via the built-in bypass).
High-frequency filters protect the mains from interference in the 150 kHz - 30 MHz range and the load (from phase-to-neutral interference up to 2.5 kHz).
BPM-01-C-B battery protection module for safe connection and servicing of the battery.
Battery charging
Batteries with a capacity of 105 Ah are charged by the charger built into the UPS with a current of 5 A.
The UPS employs modern technologies to reduce charging time and extend battery service life (intelligent charging and battery charge temperature compensation), as well as algorithms that allow the battery to be disconnected at 80-85% discharge (protection against deep discharge), notify the user of battery wear and predict autonomy time (the value is displayed in the web interface; a monitoring card is required for connection).
Control panel
The main operating parameters of the product are monitored and configured using the control panel. It includes an LCD display, four function keys and five LED indicators:
- "Status" – indicates the device operating mode;
- "Mains" – indicates mains status;
- "Bypass" – indicates a switch to bypass / ECO mode;
- "Inverter" – indicates inverter operation;
- "Battery" – shows the battery status.
The LCD display shows the input/output voltage, load percentage, battery voltage, active/apparent power and alarms.
Three battery tests can be performed (load powered from the batteries): for 10 seconds, for a set time, until fully discharged.
Monitoring tools
Local/remote monitoring is performed via a web browser or using the dedicated Shtyl Device Manager (SDM) software. This requires a board to be installed. Four board models with the following interfaces are available:
- RS-232 (Megatec protocol) and RS-485 (Modbus RTU/SHTYL protocols);
- USB and mini-USB;
- Ethernet (protocols Web/SNMP/NTP/Modbus TCP/SHTYL);
- "dry" contacts.