The single-phase UPS ST1110SL (SHTYL) AT1 is designed for use at particularly critical facilities (including railway infrastructure and metro facilities) to provide backup power and protect 10 kVA/8 kW equipment against voltage fluctuations and surges.
Due to the use of these UPS models at important facilities, a number of improvements have been made to them to increase fault tolerance.
In addition, unlike standard mass-produced devices, they have an extended warranty period of 3 years (36 months).
The ST1110SL (SHTYL) AT1 is an online UPS with double conversion technology, thanks to which the device allows:
- stabilise the input voltage over a wide range (90-295 V) with high accuracy (±2%) without switching to battery;
- instantly and without interruption transfer the load supply to the battery when the mains voltage fails;
- supply the load with a pure sine wave voltage both when operating from the mains and from the battery.
Installation and connection
The ST1110SL (SHTYL) AT1 is installed on any flat horizontal surface on swivel castors.
Power supply and load connection are provided via terminal blocks.
Standalone operation
For autonomous operation of the load, the model has built-in batteries with a capacity of 9 Ah and a charger (current 4 A).
At 100% load, the batteries will provide backup power to the connected electrical equipment for 5 minutes.
Protection
The ST1110SL (SHTYL) AT1 features modern electronic protection against:
- overload;
- short circuit;
- internal overheating.
Automatic restart of the UPS is supported after the cause of the protective shutdown has been eliminated.
The UPS also has input and output mains filters that protect consumers from high-frequency interference. A built-in varistor (2 kV, 1/50 µs) provides surge protection. In addition, the model has emergency protection against any fault. When it trips, the load is disconnected or transferred to the mains without interruption via the built-in bypass.
Indication
To monitor UPS operation, it is equipped with an intuitive LED indicator panel that does not require additional study of the operating documentation to diagnose the device status.
The device has the following indicators:
- "Status" – notifies of the device operating mode;
- "Overheating" – notifies of device overheating;
- "Mains" – notifies of the mains status;
- “Bypass” – notifies of switching to bypass/ECO mode;
- "Battery" – shows the battery status;
- load level and battery discharge indicator.
Monitoring facilities
The status of the ST1110SL (Shtyl) AT1 can be monitored both locally via the USB/RS-232 interfaces and remotely after installing an Ethernet adapter. These interfaces are located on the monitoring cards, which are installed in a special connector on the rear panel of the device.
Operation of the UPS with an installed monitoring card is conveniently monitored on a PC via a web browser or the Shtyl Device Manager (SDM) program.
Please note that the cards are not included in the basic configuration and are purchased separately.
- Specifications