The single-phase UPS ST1106SL (SHTYL) AT1 is designed for use at particularly critical facilities (including railway infrastructure and metro facilities) to provide backup power and protect 6 kVA/5.4 kW equipment against voltage fluctuations and surges.
Due to the use of these UPS models at important facilities, a number of improvements have been made to them to increase fault tolerance.
In addition, unlike standard mass-produced devices, they have an extended warranty period of 3 years (36 months).
ST1106SL (Shtyl) AT1 is an online UPS with double conversion technology, thanks to which the device allows:
- stabilise the input voltage over a wide range (90-295 V) with high accuracy (±2%) without switching to battery;
- instantly and without interruption transfer the load supply to the battery when the mains voltage fails;
- supply the load with a pure sine wave voltage both when operating from the mains and from the battery.
Installation and connection
ST1106SL (Shtyl) AT1 is installed on any flat horizontal surface on swivel castors.
Terminal blocks are provided for connecting the load and power supply.
Standalone operation
For autonomous operation of the load, the model has built-in batteries with a capacity of 9 Ah and a charger (current 4 A).
At 100% load, the batteries will provide backup power to the connected electrical equipment for 5 minutes.
Protection
ST1106SL (Shtyl) AT1 features electronic protection against:
- short circuit;
- sustained output overload;
- internal overheating.
The UPS resumes operation automatically after the cause of the protective shutdown is eliminated.
In addition, the UPS is equipped with:
- protection against impulse overvoltages (varistor – 2 kV, 1/50 µs);
- protection against high-frequency interference (100 kHz - 30 MHz);
- protection against operating faults (when triggered, the load is disconnected or transferred without interruption to the mains via the built-in bypass).
Indication
To monitor UPS operation, it is equipped with an intuitive LED indicator panel that does not require additional study of the operating documentation to diagnose the device status.
The device has the following indicators:
- "Status" – notifies of the device operating mode;
- "Overheating" – notifies of device overheating;
- "Mains" – notifies of the mains status;
- “Bypass” – notifies of switching to bypass/ECO mode;
- "Battery" – shows the battery status;
- load level and battery discharge indicator.
Monitoring facilities
The status of ST1106SL (Shtyl) AT1 can be monitored both locally via the USB/RS-232 interfaces and remotely after installing an Ethernet adapter. These interfaces are located on monitoring cards, which are installed in a special connector on the rear panel of the device.
Operation of the UPS with an installed monitoring card is conveniently monitored on a PC via a web browser or the Shtyl Device Manager (SDM) program.
Please note that the cards are not included in the basic configuration and are purchased separately.
- Specifications