The single-phase UPS SR1110L (SHTYL) AT1 is designed for use at particularly critical facilities (including railway infrastructure and metro facilities) to protect 10 kVA/8 kW equipment against power outages and unstable mains voltage.
A number of improvements have been made to these UPS models to increase fault tolerance (due to their use at critical facilities).
Unlike standard devices, they have an extended warranty period of 3 years (36 months).
The SR1110L (SHTYL) AT1 is an online topology UPS with double conversion technology, thanks to which the device allows:
- stabilise the input voltage over a wide range (90-295 V) with high accuracy (±2%) without switching to battery;
- instantly and without interruption transfer the load supply to the battery when the mains voltage fails;
- supply the load with a pure sine wave voltage.
Installation and connection
The SR1110L (SHTYL) AT1 is designed for installation in a 19-inch rack or telecommunications cabinet.
For powering the critical load, terminal blocks and three C13 computer sockets are provided. The device is connected to the input mains via terminal connections.
Standalone operation
The SR1110L (SHTYL) AT1 is equipped with built-in batteries (current 4 A) and a connector for connecting external batteries (up to 80 Ah), which provides autonomous operation of the load for 1 hour at 100% load.
Protection
The SR1110L (SHTYL) AT1 is equipped with all the necessary types of electronic protection:
- against short circuit;
- against prolonged output overload;
- against internal overheating.
The UPS is able to restore its operation automatically once the cause of the protection trip has been eliminated.
The device also has an input and output mains filter that protect the load from high-frequency interference. A built-in varistor (2 kV, 1/50 µs) provides surge protection. In addition, the uninterruptible power supply has emergency protection against any fault. When it is activated, consumers are disconnected or their power is transferred to the mains without interruption via the built-in bypass.
Indication
To monitor UPS operation, it is equipped with an intuitive LED indicator panel that does not require additional study of the operating documentation to diagnose the device status.
The device has the following indicators:
- "Status" – notifies of the device operating mode;
- "Overheating" – notifies of device overheating;
- "Mains" – notifies of the mains status;
- “Bypass” – notifies of switching to bypass/ECO mode;
- "Battery" – shows the battery status;
- load level and battery discharge indicator.
Monitoring facilities
The status of the SR1110L (Shtyl) AT1 UPS can be monitored both locally via the USB/RS-232 interfaces and remotely after installing an Ethernet adapter. These interfaces are located on the monitoring cards, which are installed in a special connector on the rear panel of the device.
Operation of the UPS with an installed monitoring card is conveniently monitored on a PC via a web browser or the Shtyl Device Manager (SDM) program.
Please note that the cards are not included in the basic configuration and are purchased separately.
- Specifications