‎+7 (499) 500-24-60
Moscow, Udaltsova St., 81, bldg 2, office 6
UPS distribution modules

Distribution module PDM-01-3CL-2A

  • Brand: Shtil
  • Product Code: PDM-01-3CL-2A
  • Availability: Pre-order
36 660 ₽

The PDM-01-3CL-2A distribution module is used together with models of single-phase UPS of the SR and STR series with a capacity of 1 kVA.

The device is intended for distributing electricity from two power sources (from two different phases or from the mains and a generator) to single-phase loads via the UPS.

The PDM-01-3CL-2A is a 3U metal enclosure that is installed in 19-inch rack rails or a telecommunications cabinet.

The device is connected to the input mains/generator using terminal connections (L, N, PE).

The load is connected to the module via terminals (L, N, PE). For this purpose, 6 circuit breakers are provided: 1xC6, 2xC4, 2xC2 and 1xC1.

The PDM-01-3CL-2A connects to the UPS via C13 and C14 connectors. The connection cables are included in the scope of delivery.

Additional functionality: input distribution device, automatic transfer switch and voltage monitoring relay. Recommended circuit breaker on the external distribution board – C16, cable – 1.5 mm².

The choice of a specific PDM series distribution module model for a UPS model of a given capacity depends on the required functionality and the number of independent power inputs. The managers of our company or our partners will help you make the exact selection of the optimal solution.

Connection diagrams

  • Specifications

General specifications
Country of manufacture Russia
Installation method rack-mount
Compatibility single-phase UPS of the SR and STR series with a capacity of 1 kVA
Accessory type distribution modules
Additional functionality main distribution board, voltage monitoring relay, ATS
Number of phases of compatible UPS 1 to 1
Input characteristics
Input mains type single-phase, three-wire (L, N, PE)
Rated input frequency, Hz 50
Rated input voltage, V 220
Output characteristics
Rated AC output voltage, V 220
Control panel and interfaces
LED indication "Mains 1", "Mains 2", "Load"
Connection
Input mains terminals (L, N, PE)
Load (output sockets) 1×C6, 2×C4, 2×C2, 1×C1
UPS connection connector type IEC-320-C14 IEC-320-C13
UPS connection cable C13-C14
Recommended cable cross-section, mm² 1,5
Recommended circuit breaker on the external panel C16
Reliability and performance characteristics
Relative humidity, % from 0 to 90 (non-condensing)
Service life, years 12
Warranty period, months 24
Operating temperature range, °C from +5 to +40
Storage temperature range, °C from -40 to +40
Mechanical characteristics
Housing colour grey
Weight, kg 4
Overall dimensions HxWxD (unpacked), mm 134x483x204

Write to us

We will reply to info@levrus.ru shortly