MWM TCG 2020 V12K is a 1,125 kW gas generator set built on the MWM TCG 2020 engine. 12 cylinders, 1,500 rpm.
Electrical efficiency 41.0 %; total efficiency with heat recovery 87.4 %.
Fuel: natural gas. The unit is used for prime and standby power at industrial sites, in municipal energy and for cogeneration: combined generation of electricity and heat.
Supply, installation, commissioning and service — LEVRUS. Scope, lead time and price are defined by the project.
Factory sheet data (natural gas, NOx 500 mg/Nm³, 50 Hz)
| Electrical output, kW (100 / 75 / 50% load) | 1,125 / 845 / 562 |
| Engine power per ISO 3046, kW | 1,155 / 869 / 582 |
| Electrical efficiency, % | 41.0 / 39.7 / 37.7 |
| Thermal efficiency (exhaust cooled to 120 °C), % | 46.4 / 47.7 / 49.5 |
| Total efficiency, % | 87.4 / 87.4 / 87.2 |
| Fuel energy input, kW | 2,743 / 2,128 / 1,490 |
| Gas flow at 100%, m³/h (calculated: energy ÷ heating value 11.2 kWh/m³) | 245 |
| Jacket water heat, kW | 587 / 446 / 306 |
| Intercooler (LT) heat, kW | 103 / 70 / 42 |
| Exhaust heat cooled to 120 °C, kW | 685 / 570 / 431 |
| Engine / generator radiation at 100%, kW | 39 / 30 |
| Exhaust temperature, °C | 477 / 504 / 535 |
| Exhaust mass flow (wet), kg/h | 6,191 / 4,777 / 3,331 |
| Combustion air flow, kg/h | 5,989 / 4,620 / 3,221 |
| Mean effective pressure, bar | 17.4 / 13.1 / 8.8 |
| Bore × stroke, mm | 170 × 195 |
| Displacement, dm³ | 53.1 |
| Compression ratio | 12.0:1 |
| Methane number / NOx emission | 70 / 500 mg/Nm³ |
| Exhaust back pressure, mbar (min / max) | 30 / 50 |
| Noise at 1 m, dB(A): exhaust / engine casing (no enclosure) | 120 ± 2.5 / 102 ± 1.0 |
| Dry weight engine / genset, kg | 4,200 / 10,450 |
| Alternator on the sheet | Marelli MJB 450 LB 4 or equal |
Source: MWM data sheet TCG 2020 V12K, natural gas, NOx 500 mg/Nm³, dated 19.01.2010. Tolerance on heat rejection ±8%, on fuel consumption +5%. The sheet dates from 2009–2010: weight and dimensions depend on the alternator, and the efficiency at the top of the page (from the MWM brochure) may differ from the sheet by tenths of a percent. Ask the manufacturer for a current offer for a project.
Gas and NOx variants in the data sheets
| Variant | Output, kW | Elec. eff., % | Total eff., % | Sheet date |
|---|---|---|---|---|
| natural gas, NOx 500 | 1,125 | 41.0 | 87.4 | 19.01.2010 |
| natural gas, NOx 250 | 1,070 | 39.5 | 87.2 | 19.01.2010 |
Output and efficiency are at 100% load. The NOx 250 mg/Nm³ variant gives lower output and efficiency; biogas and gas of another composition need a separate calculation.