  • Brand: Cummins
  • Product Code: C1400 N5C
  • Availability: Pre-order

Cummins C1400 N5C is a gas generator set built on the QSK60G engine, 50 Hz, 1,500 rpm. Electrical output 1,400 kW (1,750 kVA at 0.8 power factor).

Engine: 16 cylinders, V-type, 159 × 190 mm bore and stroke, 60.2 litres displacement, 19.4 bar BMEP, compression ratio 12,7:1. Electrical efficiency 41.8%, overall efficiency 43.1%. Fuel consumption at full load is 360 m³/h at 0,25–6.0 bar gas supply pressure; minimum methane number without derating is 64.

Heat balance: 763 kW to the high-temperature circuit, 110 kW to the low-temperature circuit and 764 kW in the exhaust at 105 °C, about 1,637 kW of recoverable heat in total. Exhaust temperature 434 °C, exhaust flow 2.17 kg/s. These figures are what a CHP design is built on.

Dimensions 5 120 × 2 230 × 2 770 mm, wet weight 15,450 kg, oil capacity 380 litres, oil consumption < 0.18 g/kWh. Control panel: PowerCommand 3.3. Time between overhauls 30,000 hours, major overhaul interval 60,000 hours.

Data from the Cummins technical table for C-series 50 Hz sets at 1,500 rpm. Price and lead time on request: the scope depends on the power export scheme, heat recovery arrangement and protection requirements.

Dimensions 5 120×2 230×2 770 mm, mass 15 450 kg. The overall height of 2.77 m exceeds the internal height of a standard container, so the set travels on an open platform or in a purpose-built module; for indoor installation the same figure sets the door and hall height requirements.

Dimensions and weight are taken from Cummins data sheet D-3347e (500 mg/Nm³, methane number 68) for a set with standard features; other configurations (radiator, silencer, container) differ.

Gas requirement: methane number not below 64 without derating, inlet pressure 0,25–6.0 bar, and calorific value within the design range. Where methane number is lower, the set loses output and the duty has to be agreed with the factory rather than adjusted on site: on low-methane gas knock limits load before it shows up in fuel consumption.

Builds and what they change

Each C-series model is built in several variants. The difference is not the rating but the acceptable gas composition, the NOx level and the high-temperature circuit temperature. The build decides whether the set delivers full output on your gas and which heat grade you can recover.

BuildFuelMin. methane numberNOx, mg/Nm³HT/LT, °CNote
D-3347natural gas6850090/40High-Efficiency
D-3348natural gas6425090/40High-Efficiency
D-3357natural gas6635090/40High-Efficiency
D-3358natural gas7250090/40High-Efficiency

Methane number is the gas knock resistance rated under the AVL method. The lower it is, the earlier load has to be limited, which is why natural-gas and low-calorific-gas builds differ in compression ratio rather than only in controller settings.

NOx comes in three levels: 250, 350 and 500 mg/Nm³, set by the emission permit for the site. For the same gas the 350 mg/Nm³ build usually asks for a different methane number than the 500 mg/Nm³ build, as the table shows.

HT/LT are the jacket-water temperatures in the high- and low-temperature circuits. A 110/50 °C circuit supplies heat usable by a wider set of consumers than 95/50 °C, but needs different heat-exchange equipment; the choice follows the heat scheme, not spare margin.

High-Efficiency builds have higher electrical efficiency and are approved for parallel operation with the grid only. They are not used in island mode — this is a factory limitation, not our caution.

The build is agreed per project: gas, emission limits, heat recovery scheme. Price and lead time depend on the code, so a request is best started from the gas analysis and the emission permit rather than from the kW figure.

How to read the designation, how builds differ by methane number and NOx, and how to size heat recovery — see Cummins C-series 50 Hz: choosing the build.


Gas generator set
Electrical output, kW 1400
Apparent power, kVA 1750
Fuel natural gas
Frequency, Hz 50
Speed, rpm 1 500
Voltage, V 400 / 6 300 / 10 500
Weight, kg 15 450
Number of cylinders 16
Displacement, l 60,2
Bore / stroke, mm 159 × 190
Dimensions (L×W×H), mm 5 120 × 2 230 × 2 770
NOx emission, mg/Nm³ 250 / 350 / 500
Main
Amount of heat dissipated, kW 229
Amount of heat in exhaust at t_out=105ºC 764
Amount of heat in high-temperature circuit, kW 763
Amount of heat in low-temperature circuit, kW 110
Compression ratios 12,7:1
Control panel type PowerCommand 3.3
Electrical efficiency, % 41,8
Engine model QSK60G
Exhaust gas temperature, °C 434
Fuel consumption at 100 % load, m3/hour 360
Gas supply pressure, Bar 0,25–6,0
Mechanical efficiency, % 43,1
Minimum methane number without power derating 64–72
Oil consumption, g/kW.h < 0,18
Oil system capacity, l 380