This model is discontinued. It is absent from the current Cummins 50 Hz range cards (2025) and its page on the manufacturer website is no longer available. The card is kept for reference by owners of sets bought earlier. Closest models in the current range: C450D5 (QSG12-G1) and C450D5EB (QSZ13-G7). For spare parts and service please quote the genset serial number.
Cummins C450D5E diesel generator set, 50 Hz: 360 kW / 450 kVA standby and 327 kW / 409 kVA prime. Engine QSX15G8, alternator HC5C, factory panel code 46055 for large sets; the function set is confirmed by the build data sheet.
Designation: C is the Cummins series, 450 the frame size, D diesel and 5 50 Hz. The QSX15G8 engine is 6-cylinder 15 litre, electronically managed.
The two ratings are different duty classes, not a margin. Standby allows variable load for a limited number of hours per year with no overload; prime allows continuous operation with a 10 % overload for one hour in twelve. The gap between 360 and 327 kW is exactly those 10 %, and the choice follows the way the site will run, not the larger figure: using a standby rating as prime voids the factory warranty.
The 100–700 kW class carries most standby projects. What matters here is not the nameplate but the dynamics: starting of pumps and fans, load acceptance from a UPS and behaviour on step load. The factory panel code 46055 for large sets; the function set is confirmed by the build data sheet determines which protections and interfaces are available.
Data from the factory table: standby and prime ratings, engine, alternator, panel, canopy availability (EU/TAL — 15). Price and lead time on request: the scope depends on the power export scheme, the ATS type and protection requirements.
Factory data sheet
| Bore × stroke, mm | 137 × 169 |
| Compression ratio | 17:1 |
| BMEP, kPa (standby / prime) | 2675 / 2371 |
| Piston speed, m/s | 8.4 |
| Engine oil capacity, L | 91 |
| Fuel consumption, L/h, standby (¼ / ½ / ¾ / full) | 31.03 / 52.68 / 74.00 / 94.15 |
| Fuel consumption, L/h, prime (¼ / ½ / ¾ / full) | 29.25 / 48.56 / 67.85 / 86.81 |
| Combustion air, m³/min (standby / prime) | 36.27 / 32.5 |
| Exhaust flow at rated load, m³/min (standby / prime) | 82.2 / 75.3 |
| Exhaust temperature, °C (standby / prime) | 515 / 488 |
| Max exhaust back pressure, kPa | 10.2 |
| Radiator fan load, kW | 16 |
| Heat rejected to room, BTU/min (standby / prime) | 16 700 / 13 700 |
| Dimensions L × W × H, mm, open set | 3 427 × 1 500 × 2 066 |
| Dimensions L × W × H, mm, canopy | 5 106 × 1 553 × 2 447 |
| Dry weight, kg (open / canopy) | 3 987 / 5 292 |
| Wet weight, kg (open / canopy) | 4 825 / 6 130 |
Source: Cummins specification sheet DS347-CPGK-RevAR. Figures are factory values; request the current outline drawing for your exact configuration, because weight and size change with radiator, silencer, tank and canopy.
Noise
| Enclosed sound power level LWA, dB(A) | 98 |
| Sound pressure at 7 m, enclosed, dB(A) (75 / 100 / 110 % load) | 69 / 71 / 71 |
| Sound pressure at 15 m, enclosed, dB(A) (75 / 100 / 110 % load) | 64 / 66 / 66 |
| Open set average sound pressure at 1 m, dB(A) (at 100 % load) | 101 |
| Open set sound power level, dB(A) (at 100 % load) | 117 |
Source: Cummins noise data sheets ND50-CS550-RevF / ND50-OS550-RevG. Factory values measured per ISO 8528-10 and Directive 2000/14/EC; levels at other distances and inside a room are calculated separately.